23
202P4 M25P
Electrical Adjustments
0. General
When carry-out the electrical settings in many cases a video
signal must be applied to the monitor. A computer with :
- ATI GPT-1600 (4822 397 10065), Mach 64 (up to 115kHz)
are used as the video signal source. The signal patterns are
selected from the "service test software" package, see user
guide 4822 727 21046 (GPT-1600).
0.1 This monitor has 36 factory-preset modes as below
.
0.2 With normal VGA card:
If not using the ATI card during repair or alignment, The
service engineer also can use this service test software
adapting with normal standard VGA adaptor and using
standard VGA mode 640 x 480, 31.5 kHz/60 Hz (only) as
signal source.
0.3 AC/DC Measurement:
The measurements for AC waveform and DC figure is based
on 640 x 480 31.5 kHz/60 Hz resolution mode with test
pattern "gray scale".
Power input: 110V AC
1. B+ supply voltage (3157) 230Vdc
- Apply a video signal in the 1024 x 768 with 69 kHz/85Hz
mode.
- Select the "cross-hatch" pattern.
- Set the brightness control and the contrast control to the
minimum
position.
- Pre-set trimming potentiometer 3157(B+) and 3698(EHT)
in mid-position.
- Set Vg2 (screen) to fully Counter-clockwise (zero
beamcurrent).
- Connect a dc voltmeter between the joint of capacitor 2154
and ground (common ground).
- Set the B+ trimming potentiometer 3157 so that the reading
on the dc voltmeter is 230 V +/- 0.2 Vdc.
2. High-voltage EHT (3698)
- Apply a video signal in the 1024 x 768 with 68.7 kHz/85Hz
mode.
- Select the "cross-hatch" pattern.
- Set the brightness control and the contrast control to the
minimum position.
- Turn off the power.
- Connect a "high-voltage voltmeter" between the high-
voltage connection of the picture tube and earth.
- Turn on the power.
- Set the EHT trimming potentiometer 3661 so that the "high-
voltage voltmeter" reads 27.0 kV +/- 0.2 kV .
- Turn off the power.
- Remove the "high-voltage voltmeter" from the picture tube.
- Turn on the power again.
4.5 Adjust function controls "
" to center position except
for contrast control which should be set to MAX.
- Turn off monitor (don't turn off PC)
- Press "
" and "
" simultaneously on the front
control panel, then press "
",wait till the OSD menu
with characters " factory mode (below OSD menu)" come
on the screen of monitor.
- If OSD menu disappears on the screen of monitor, press
"
" again (anytime), then the OSD menu comes on the
screen again.
- using "
" : to select OSD menu.
: to increase or decrease the setting.
- Using "
" to confirm the selection.
5. To access factory mode:
3. Monitor the following auxiliary voltages.
4. General conditions for alignment
SOURCE ACROSS C2157 - 13.0V +/- 0.5VDC.
SOURCE ACROSS C2172 + 13.0V +/- 0.5VDC.
SOURCE ACROSS C2156 - 6.4 V+/- 0.2VDC.
SOURCE ACROSS C2152 + 193.0V +/- 1.5VDC.
SOURCE ACROSS C2154 + 79.0 V +/- 0.2VDC.
4.1 During all alignments, supply a distortion free AC mains
voltage to set via an isolating transformer with low internal
impedance.
4.2 Align in pre-warmed condition, at least 30 minutes warm-
up with nominal picture brightness.
4.3 Purity, geometry and subsequent alignments should be
carried out in magnetic cage with correct magnetic field.
Northern hemisphere : H=0, V=430+/-50 mG, Z=0
Southern hemisphere : H=0, V=-520+/-50 mG, Z=0
Equatorial Support
: H=0, V=0
mG, Z=0
4.4 All voltages are to be measured or applied with respect to
ground.
Note: Do not use heatsink as ground.
SOURCE ACROSS C2362 +
8.0V +/- 0.5 VDC
SOURCE ACROSS C2143 +
5.0V +/- 0.5 VDC
SOURCE ACROSS C2361 + 12.0V +/- 0.5 VDC
SOURCE ACROSS C2134 + 15.1V +/- 1.0 VDC
SOURCE ACROSS C2137 - 15.4V +/- 1.0 VDC
SOURCE ACROSS D6143 “+“
6.1V +/- 0.5 VDC
SOURCE ACROSS C2131 + 230.0V +/- 1.5 VDC
SOURCE ACROSS C2133 + 82.0V +/- 2.0 VDC
MODEL
SELECT
Factory
Mode
Indicator
CM25 PLUS V0.55 20011128
00195
RESOLUTION
f h
f v
RESOLUTION
f h
f v
640 x 480
31.469 kHz
59.941 Hz
1152 x 870
68.681 kHz
74.979 Hz
720 x 400
31.468 kHz
70.084 Hz
1856 x 1392
124.185KHz
85.000Hz
640 x 480
37.500 KHz
75.000 Hz
1920 x1440
128.520KHz
85.000Hz
640 x 480
37.861 kHz
72.810 Hz
1600 x 1200
75.000 kHz
60.000 Hz
800x600
37.879 kHz
60.317Hz
1280 x1024
79.976 kHz
75.024 Hz
640 x 480
43.269 kHz
85.008 Hz
1600 x 1200
81.250 kHz
65.000 Hz
800 x 600
46.875 kHz
75.000 Hz
1792 x 1344
83.640 kHz
59.999 Hz
800 x 600
48.077 kHz
72.188 Hz
1920 x1440
120.56HKz
80.000Hz
1024 x 768
48.363 kHz
60.004 Hz
1856 x 1392
86.333 kHz
59.995 Hz
832 x 624
49.722 kHz
74.546 Hz
1600 x 1200
87.500 kHz
70.000 Hz
640 x 480
50.628 kHz
100.10 Hz
1920 x 1440
90.000 kHz
60.000 Hz
800 x 600
53.674 kHz
85.061 Hz
1280 x 1024
91.146 kHz
85.024 Hz
1024 x 768
56.476 kHz
70.069 Hz
1600 x 1200
93.750 kHz
75.000 Hz
1792 x 1344
119.935KHz
85.000Hz
1600 x 1200
106.250 kHz
85.000 Hz
1024 x 768
60.023 kHz
75.029 Hz
1792 x 1344
106.270 kHz
74.997 Hz
800 x 600
63.923 kHz
100.00 Hz
1920 x 1440
112.5 kHz
75.000 Hz
1280 x 1024
63.981 kHz
60.020 Hz
2048 x 1536
120.450 kHz
75.000 Hz
1024 x 768
68.677 kHz
84.997 Hz
2048 x 1536
130KHz
80Hz
Summary of Contents for 202P4
Page 31: ...Terminal Schematic Diagram A1 Go to cover page ...
Page 33: ......
Page 34: ......
Page 35: ...Go to cover page ...
Page 37: ...Key Control Schematic Diagram 202P4 M25P 32 34 Go to cover page E ...
Page 39: ...Go to cover page ...
Page 41: ......
Page 43: ...Power Schematic Diagram C C1 C6 C2 C7 C3 C4 C5 C9 C8 Go to cover page ...
Page 45: ...Drive Schematic Diagram 202P4 M25P 32 38 D Go to cover page ...
Page 91: ...83 202P4 M25P Repair Flow Chart Go to cover page 7 0 2 ...