Failed or success in including/excluding the node ID can be viewed from the Z-Wave
Controller.
LED Indication
To distinguish what mode the PAN08 is in, view from the LED for identification.
State Type
LED Indication
Motor
activate
No matter up or down, close or open, Led will flash every second
while Motor activate.
When S1 or S2 close to L, the LED will flash even when the motor
stop by itself, this is to let user know the S1 or S2 still close and not
been release yet.
No node ID
Under normal operation, when the PAN08 has not been allocated a
node ID, the LED flashes on and off alternately at 2-second
intervals. By pressing S1 S2 or Include button, it will stop flashing
temporarily.
Learning
When PAN08 is in learning mode, LED flashes on and off
alternately and repeatedly at 0.5 second intervals.
Overload
When overload state occurs, the PAN08 is disabled and LED
flashes on and off alternately at 0.2 second intervals. PAN08 will
send alarm_type=8 alarm_Level=0xFF to Group1, Overload state
can be cleared by disconnect and reconnect the PAN08 to the main
power
Choosing a Suitable Location
1. Do not locate the PAN08 facing direct sunlight, humid or dusty place.
2. The suitable ambient temperature for the PAN08 is 0°C~40°C.
3. Do not locate the PAN08 where exists combustible substances or any source of
heat, e.g. fires, radiators, boiler etc.
4. After putting it into use, the body of PAN08 will become a little bit hot of which
phenomenon is normal.
Installation and operation
1. Put the in wall PAN08 into a wall box and connect the AC power wire L,N to
PAN08 connector L, N.
2. Connect the wall switch to the PAN08 as Fig1 .
3