TOP(0xFF). The easy way to stop this moving is short pressing S2. When S2 is
short pressed, the shutter will move down toward BOTTON(0x00). While in this
moving short pressed S2 again, the shutter just keep moving down toward
BOTTON(0x00). The easy way to stop this moving is short pressing S1.
When in Two Push Button switch type, S1 or S2 are pressed and not
released, and PAN08 receive any control moving command from Z-Wave RF
(Ex.
BASIC_SET
、
BINARY_SWITCH_SET
、
MULTILEVEL_SWITCH_SET
、
MULTILE
VEL_SWITCH_START_LEVEL_CHANGE or
MULTILEVEL_SWITCH_STOP_LEVEL_CHANGE or
SCENE_ACTIVATION_SET), PAN08 won’t do any change in position but
report alarm to Group1 (Alarm_Type=1, Alarm_level =0xFF), this indicate
that the S1 or S2 not been release.
ATT. : For avoid misunderstanding that RF command dose not work, it is
recommended to check the status of S1 and S2.
7-6 Level Report mode
Mode 1 : In 5 seconds period after controlled by a moving command, it will report the
destination level when received request command. Out of the 5 seconds
period, it will report the actual level of the shutter when received request
command.
Mode 2 : Whenever the shutter move pass a 10 percent level, it will auto report the
level to Group 1 node.
8
Command Classes
The Switch supports Command Classes including…
* COMMAND_CLASS_ZWAVEPLUS_INFO
* COMMAND_CLASS_VERSION_V2
* COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
* COMMAND_CLASS_DEVICE_RESET_LOCALLY
* COMMAND_CLASS_ASSOCIATION_V2
* COMMAND_CLASS_ASSOCIATION_GRP_INFO
* COMMAND_CLASS_POWERLEVEL
* COMMAND_CLASS_SWITCH_BINARY
* COMMAND_CLASS_BASIC
* COMMAND_CLASS_SWITCH_MULTILEVEL_V3
* COMMAND_CLASS_CONFIGURATION
* COMMAND_CLASS_ALARM
* COMMAND_CLASS_METER_V3
* COMMAND_CLASS_SCENE_ACTIVATION
* COMMAND_CLASS_SCENE_ACTUATOR_CONF
* COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
Troubleshooting
Symptom
Cause of Failure
Recommendation
The PAN08 not working
1. The PAN08 is not
1. Check power connections
12