background image

This product can be operated in any Z-Wave™ network with other Z-Wave™ certified

devices from other manufacturers. All non-battery operating nodes within the network

will act as repeaters regardless of the vendor in order to increase reliability of the net-

work.

The table below provides a summary of operations of basic Z-Wave™ functions. 

Please refer to the instructions for your Z-Wave™ Certified Primary Controller to ac-

cess the Setup function, and to Add/Remove/associate devices.

Function

Description

Annotation

No node ID

The Z-Wave

 Controller does not allocate a 

node ID to the Switch.

LED light flashes once 

every one second and 

last for 30 seconds.

Add

(Classic Inclu-

sion)

1.

Put your Z-Wave

 controller into

 

inclu-

sion mode by following the

 

instructions 

provided by the controller manufacturer.

2.

Press the include button three times within

3 seconds to enter inclusion mode.

SmartStart

1.

The product has a DSK string. Key in the 

first five digits to initiate the SmartStart 

process, or scan QR code. 

Ex: DSK: 18112-24021- 48001-62259-

57092-27453-08187-47408

2.

 SmartStart

 enabled products can be added

into a Z-Wave

 network by scanning the

Z-Wave

 QR Code on the product, with 

a controller providing SmartStart inclusion.

No further action is required and the 

SmartStart product will be added automat-

ically to the closest network within 10 min-

utes of being switched on.

Notice:

The QR Code can be found on the device 

PAD19 or in the box.

Remove (Ex-

clusion)

1.

Put your Z-Wave

 controller into

 

exclu-

sion mode by following the instructions 

provided by the

 

controller manufacturer.

2.

Press the include button three times within

3 seconds to enter exclusion mode.

3.

Node ID will be excluded.

LED light flashes once 

every one second and 

last for 30 seconds

Reset

1.

Press the include button four times within 

3 seconds and hold on the button press 

without releasing.

LED light will be on sta-

tus

4

Summary of Contents for PAD19

Page 1: ...re for the products firmware up grade Main features of Philio s In Wall Micro dimmer Compatible with any Z Wave or Z Wave Plus Controller Supports Z Wave network Security Modes S2 To be installed with LED dimmer or incandescent lamp A single live without neutral lead To be installed in wall switch boxes Specification Operating Rated 100 240Vac 50Hz 60Hz 0 7A Output load Max 0 7A 100 240VAC 160W Di...

Page 2: ...ectrical wire properly 2 The dimmer break down 1 Check power connections 2 Don t open up the dimmer and send it for repair The device can not join to Z Wave network The device may in a Z Wave network Exclude the device then include again Flashing during dimming Minimum load is less than 20W Replace larger load Installation steps There are two wiring methods for PAD19 A Connect the AC L line and th...

Page 3: ...ays performed with disconnected voltage Choosing a Suitable Location 1 Do NOT place the module device direct under sunlight in a humid place or in any location where they may contact moisture dirt dust 2 Do NOT place the module device where exists combustible substance or any source of heat fires radiators boiler etc 3 When the module device be used the module device might get warm This is a norma...

Page 4: ...in 3 seconds to enter inclusion mode SmartStart 1 The product has a DSK string Key in the first five digits to initiate the SmartStart process or scan QR code Ex DSK 18112 24021 48001 62259 57092 27453 08187 47408 2 SmartStart enabled products can be added into a Z Wave network by scanning the Z Wave QR Code on the product with a controller providing SmartStart inclusion No further action is requi...

Page 5: ... has not been allocated a node ID the LED light will flash on and off alternately at 1 second intervals By press ing the On Off button LED light will stop flashing temporarily Learning Flashes when learning is successful Over load LED flashes one time every 0 4 seconds Manual dim level control Long press the button the light will increase the lighting slowly Short press the button the light will b...

Page 6: ...and DEVICE_RESET_LOCALLY_NOTIFICATION 1 Grouping 1 Lifeline Maximum 5 nodes 2 MULTILEVEL_SWITCH_REPORT When on or off state has been changed it will send Multilevel Switch Report to the nodes of Grouping 1 3 NOTIFICATION_REPORT When overload occurred 4 DEVICE_RESET_LOCALLY_NOTIFICATION When PAD19 is reset manually it will send DEVICE_RESET_LOCALLY_NOTIFICATION to the nodes of group 1 Z Wave config...

Page 7: ...he network will act as repeaters regard less of vendor to increase reliability of the network Over The Air Firmware Update The device support the Z Wave firmware update via OTA Let the Z WaveTM Controller into the firmware update mode choose the hex file to update Wait for 10 15 minutes At that time please don t remove the power otherwise it will cause the firmware broken and the device will no fu...

Page 8: ...stallation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interfer ence to radio communications However there is no guarantee that interference will not occur in a particular installa tion If this equipment does cause harmful interference to radio or television recep tion which can be determin...

Page 9: ...低功率射頻器材之使用不得影響飛航安全及干擾合法通信 經發現有干擾現象時 應 立即停用 並改善至無干擾時方得繼續使用 前述合法通信 指依電信管理法規定作業之無線電通信 低功率射頻器材須忍受合法通 信或工業 科學及醫療用電波輻射性電機設備之干擾 9 ...

Reviews: