mum level
4
Minimum level
1
0
0~(Maxi-
mum level-
1)
To set dimming level minimum
value. Dimming level will directly
go to 0% when dimming value is
lower than the setting value.
Setting value:
Cannot be higher than the Maxi-
mum level
5
Basic duration
set
1
2
0~127
Unit: second
To set dimming finished duration
time when physical switch used.
Ex: When setting is 2, it will take 2
seconds from switch on action to
dimming finished.
6
Switch Set
1
1
0~1
0: L
ong Press:dimmer
Short Press:ON/OFF
1:
Toggle(no dimmer function)
Notice 1:
Always remove a Z-Wave
™
device before trying to add it to
a Z-Wave
™
network.
Notice 2:
This product can be operated in any Z-Wave
™
network with
other Z-Wave
™
certified devices from other manufacturers. All non-
battery operated nodes within the network will act as repeaters regard-
less of vendor to increase reliability of the network.
Over The Air Firmware Update
The device support the Z-Wave
™
firmware update via OTA.
Let the Z-Wave
TM
Controller into the firmware update mode, choose
the hex file to update. Wait for 10~15 minutes.
At that time,
please don't remove the power
, otherwise it will
cause the firmware broken, and the device will no function.
Result will show in Z-Wave
TM
Controller log.
Z-Wave
™
Supported Command Class
Command Class
Version
Required Security Class
Z-Wave
™
Plus Info
2
None
Security
1
None
Security 2
1
None
Supervision
1
None
Transport Service
2
None
Association
2
Highest granted Security Class
Association Group Informa-
tion
3
Highest granted Security Class
Device Reset Locally
1
Highest granted Security Class
Firmware Update Meta Data
5
Highest granted Security Class
Indicator
3
Highest granted Security Class
Manufacturer Specific
2
Highest granted Security Class