![Philio PAD19 User Manual Download Page 2](http://html.mh-extra.com/html/philio/pad19/pad19_user-manual_1537956002.webp)
RF Maximum Power
+10dBm (Peak), -10dBm (Average)
Transmission Range
Up to 40m indoors or up to 100m outdoors
(depending on building materials)
OTA
Support
Dimensions
47.5x39x16 mm
Wire
0.75mm² ; 18AWG
** Specifications are subject to change and improvement without notice.
Troubleshooting
Symptom
Cause of Failure
Recommendation
The dimmer does
not work and LED
off
1.The dimmer does
not connect the
electrical wire
properly
2.The dimmer break
down
1. Check power connections
2. Don’t open up the dimmer
and send it for repair.
The device can
not join to Z-
Wave
™
network
The device may in a
Z-Wave
™
network.
Exclude the device then include
again.
Flashing during
dimming
Minimum load is
less than 20W
Replace larger load
Installation steps
There are two wiring methods for PAD19.
A. Connect the AC L line and the bulb load end.
B. S1 Can be connect externally switches.C. COM is for S1 connect port.
Fig 1. Assembling & Wiring
Fig 2. Assembling & Wiring
Important: Read all instructions prior to installation
2