Power Cord Requirements:
Power cords must meet the requirements for the country it is intended to be used.
U.S.A. and
Canada
▪
The cord must have a minimum of 10A rated current competence
▪
The cord must be CSA or UL approved
▪
The minimum requirement for the flexible cord is:
o
18 AWG (10A)
o
Three-Conductor (Line, Neutral, Ground)
o
Type SV (stranded Vacuum Rubber Jacketed) or SJ
(stranded Junior Rubber Jacketed) or SVT (Stranded
Vacuum Rubber Jacketed Thermoplastic) or SJT (Stranded
Junior Thermoplastic)
▪
The plus must be earth-grounded with a NEMA 5-15 (15A, 125V) or
NEMA 6-15P (15A, 250V) configuration
Europe
Switzerland
▪
The supply plug must comply with SEV/ASE 1011
Denmark
▪
The supply plug must comply with section 108-2-D1, standard DK2-
1a or DK2-5a
United Kingdom
▪
The Midspan is covered by General Approval (section 16.16.060,
NS/G/12345/J100003, for indirect connection to a public
telecommunication system
France and Peru
▪
IT equipment cannot power this device. In the case of an IT powered
device, the unite needs to be powered by 230V through an isolation
transformer with a ratio of 1:1 and the secondary connection
(Neutral) is properly grounded
▪
The Midspan must have access to a nearby power outlet. By disconnecting the power cord
from the outlet, you will eliminate power from the device.
▪
The flexible cord that connects to the Midspan must have a configuration to connect with an
EN60320/IEC320 inlet connector.
▪
According to the EN60950/IEC 950 specifications this device functions under SELV (Safety
Extra Low Voltage) conditions. The conditions are true if the equipment and the connected
device functions under SELV conditions.