Appendix A: Troubleshooting
If you are having problems using the AutoSort Connect, look up the problem in the following table,
and then follow the instructions to resolve the problem. If you have a problem that is not listed
here, try to determine what might be causing the problem. If you cannot resolve the problem, call
your dealer or Phason Technical Support (see the last page of the manual.)
Problem/message
Possible cause
Resolution
The display does not light up There is no power.
Make sure there is power to the unit. See
The ribbon cable is not
connected.
Make sure the ribbon cable is connected. See
The display shows a positive
or negative weight when there
is nothing on the scale.
If the value is a small amount (less than five
pounds/kilograms, press
0
to adjust it.
If the value is a large amount, recalibrate the scale. See
Appendix B: Calibrating the scale head
Troubleshooting incorrect weights
The displayed weight
fluctuates greatly (for
example, -100 pounds, then
500 pounds) when there is
nothing on the scale.
The load cell is not
properly connected to the
scale head.
Measure the voltage from the
+ excitation
to the
–
excitation
terminals. The voltage should be about 5 VDC.
Troubleshooting incorrect weights
The display does not register
a weight when there is weight
on the scale.
The load cell is not
properly connected to the
scale head.
Measure the voltage from the
+ excitation
to the
–
excitation
terminals. The voltage should be about 5 VDC.
Troubleshooting incorrect weights
Animals sort straight correctly
but left and right are
backward.
The hose connections are
incorrect.
Correct the hose connections. See
Animals are being sorted in
the wrong direction.
The sort settings are
incorrect.
Make sure the sort settings are correct for the size of
animals. For more information, go to
Settings
on the
AutoSort.
The hose connections do
not match the power off
configuration.
Make sure the power off settings match the hose
connections. See
Connect equipment to the solenoid
page 10 and go to
Configuration > Power off
on the
AutoSort.
The right and left exit gates
bang into each other.
The hose connections do
not match the power off
configuration.
Make sure the power off settings match the hose
connections. See
Connect equipment to the solenoid
page 10 and
Configuration > Power off
on the AutoSort.