28
2.4.2
Motor Power Output Installation
Step 1: Find out the Motor Power Output Terminals
PE, A, B and C, these are the four terminals called Motor Power Output Terminals. AxN Size5 Drive’s
Motor Power Output Terminals are in the Motor Power Output Port (P2) which is on the bottom
of the drive. Refer to the following figures for exact locations and terminal Assignment.
Step 2
:
Install Phase Wires (U, V and W)
Use a 6mm blade screw driver to loosen the screws on U, V and W Terminals which are in the
drive’s Motor Power Output Port (P2). Insert the motor power output cable’s phase wires into the
corresponding terminals:
U to A, V to B and W to C
. Then use a 6mm blade screw driver to tight
the screws.
WARNING: The correspondence between the Motor Power Output wires and terminals should
be adhered! Otherwise the motor cannot work properly!