Operating Instructions & Parts Manual

 

 

Page 9 

 

ASTM Hardness Conversion Chart 

Rockwell C Hardness Range 

Approximate Hardness Conversion Numbers for Non-Austenitic Steels, According to ASTM E-140 

The Conversion Values contained herein should be considered approximate only and may be inaccurate for specific applications 

C A D 

15N 

30N 

45N 

Vickers Knoop  Brinell Tensile 

150 kgt 

60 kgt 

100kgt 

15kgt 

30 kgt 

45 kgt 

Hardness Hardness Hardness Strength 

diamond diamond diamond diamond diamond diamond 

500gr 

3000kgt  1000 

lbs/ 

 

 

 

and over 

10mm ball 

square in 

68  85.6 76.9 93.2 84.4 75.4  940  920  .. 

.. 

67  85.0 76.1 92.9 83.6 74.2  900  895  .. 

.. 

66  84.5 75.4 92.5 82.8 73.3  865  870  .. 

.. 

65  83.9 74.5 92.2 81.9 72.0  832  846 (739)   
64  83.4 73.8 91.8 81.1 71.0  800  822 (722)   
63  82.8 73.0 91.4 80.1 69.9  772  799 (705)   
62  82.3 72.2 91.1 79.3 68.8  745  776 (688)   
61  81.8 71.5 90.7 78.4 67.7  720  754 (670)   
60  81.2 70.7 90.2 77.5 66.6  697  732 (654)   
59  80.7 69.9 89.8 76.6 65.5  674  710 (634) 351 
58  80.1 69.2 89.3 75.7 64.3  653  690  615  338 
57  79.6 68.5 88.9 74.8 63.2  633  670  595  325 
56  79.0 67.7 88.3 73.9 62.0  613  650  577  313 
55  78.5 66.9 87.9 73.0 60.9  595  630  560  301 
54  78.0 66.1 87.4 72.0 59.8  577  612  543  292 
53  77.4 65.4 86.9 71.2 58.6  560  594  525  283 
52  76.8 64.6 84.4 70.2 57.4  544  576  512  273 
51  76.3 63.8 85.9 69.4 56.1  528  558  496  264 
50  75.9 63.1 85.5 68.5 55.0  513  542  481  255 
49  75.2 62.1 85.0 67.6 53.8  498  526  469  246 
48  74.7 61.4 84.6 66.7 52.5  484  510  455  237 
47  74.1 60.8 83.9 65.8 51.4  471  495  443  229 
46 73.6 60 83.5 64.8 50.3 458 480 432 221 
45  73.1 59.2 83.0 64.0 49.0  446  466  421  215 
44  72.5 58.5 82.5 63.1 47.8  434  452  409  208 
43  72.0 57.7 82.0 62.2 46.7  423  438  400  201 
42  71.5 56.9 81.5 61.3 45.5  412  426  390  195 
41  70.9 56.2 80.9 60.4 44.3  402  414  381  188 
40  70.4 55.4 80.4 59.5 43.1  392  402  371  182 
39  69.9 54.6 79.9 58.6 41.9  382  391  362  177 
38  69.4 53.8 79.4 57.7 40.8  372  380  353  171 
37  68.9 53.1 78.8 56.8 39.6  363  370  344  166 
36  68.4 52.3 78.3 55.9 38.4  354  360  336  161 
35  67.9 51.5 77.7 55.0 37.2  345  351  327  156 
34  67.4 50.8 77.2 54.2 36.1  336  342  319  152 
33  66.8 50.0 76.6 53.3 34.9  327  334  311  149 
32  66.3 49.2 76.1 52.1 33.7  318  326  301  146 
31  65.8 48.4 75.6 51.3 32.5  310  318  294  141 
30  65.3 47.7 75.0 50.4 31.3  302  311  286  138 
29  64.8 47.0 74.5 49.5 30.1  294  304  279  135 
28  64.3 46.1 73.9 48.6 28.9  286  297  271  131 
27  63.8 45.2 73.3 47.7 27.8  279  290  264  128 
26  63.3 44.6 72.8 46.8 26.7  272  284  258  125 
25  62.8 43.8 72.2 45.9 25.5  266  278  253  123 
24  62.4 43.1 71.6 45.0 24.3  260  272  247  119 
23  62.0 42.1 71.0 44.0 23.1  254  266  243  117 
22  61.5 41.6 70.5 43.2 22.0  248  261  237  115 
21  61.0 40.9 69.9 42.3 20.7  243  256  231  112 
20  60.5 40.1 69.4 41.5 19.6  238  251  226  110 

 

 

 

 

 

 

 

 

 

 

Hardness values in Brackets are outside the range recommended for Brinell testing in  

ASTM E-10.The above tables is from ASTM E-110 except values for E-scale and Tensile Strength  

which are not from or according to ASTM Standards. 

 

Reprinted from the Annual Book of ASTM Standards, 

Copyright American Society for Testing and Materials, 100 Barr Harbor Drive,West Conshohocken,PA 19428-2959. 

Summary of Contents for 900-345

Page 1: ...esters Model No 900 345 Analog Superficial Rockwell Hardness Tester Model No 900 345D Superficial Rockwell Hardness Tester w Digital Indicator Operation Manual 21 Industrial Ave Upper Saddle River NJ...

Page 2: ...ing a 120 diamond indentor in the N scale Soft thin materials are tested using a 1 16 carbide ball indentor in the T scale This tester features a weight adjustment knob for quick and easy adjustments...

Page 3: ...on 1 Remove Top crate cover from base Carefully lift straight up to avoid scratching the side of the machine 2 Remove the tool kit and manual from the base of the crate 3 Remove plastic machine cover...

Page 4: ...Operating Instructions Parts Manual Page 4 Example of weights hung on support bar Weight 3 Weight 1 Weight 2 Rockwell B Indentor 1 16 Carbide Ball Rockwell C Indentor Diamond...

Page 5: ...in front of it there is a small metal access plate held on by 2 small screws Remove the screws and plate to expose the valve and reservoir Push the Load Unload handle towards the back of the machine...

Page 6: ...material hardness to be tested see Figure 3 Mount the required indentor in the indentor holder using the set screw Fig 6 Ref Nos 27 and 28 on the side of the holder Test Procedure Test procedure consi...

Page 7: ...aking a very slight turn Counter Clockwise on the set screw you will see the large needle on the dial begin to turn counter clockwise on the dial Continue turning until there is no more contact betwee...

Page 8: ...Elevation screw cover top are interfering with specimen anvil or elevation screw 3 Indentor is damaged 4 Dash pot is low on oil 1 Be sure the anvil top of elevation screw threaded collar indentor and...

Page 9: ...7 47 74 1 60 8 83 9 65 8 51 4 471 495 443 229 46 73 6 60 83 5 64 8 50 3 458 480 432 221 45 73 1 59 2 83 0 64 0 49 0 446 466 421 215 44 72 5 58 5 82 5 63 1 47 8 434 452 409 208 43 72 0 57 7 82 0 62 2 4...

Page 10: ...5 82 142 84 51 7 87 9 72 4 56 8 162 176 162 81 140 83 51 1 87 6 71 8 55 8 159 173 159 80 137 82 50 6 87 3 71 1 54 8 156 170 156 76 135 81 50 86 9 70 4 53 8 153 167 153 73 133 80 49 5 86 6 69 7 52 8 15...

Page 11: ...3 37 29 5 79 72 7 41 0 9 6 94 72 36 29 1 78 5 72 3 40 3 8 6 93 72 35 28 7 78 0 72 0 39 6 7 6 92 71 34 28 2 77 0 71 7 39 0 6 6 91 70 33 27 8 76 6 71 4 38 3 5 6 90 69 32 27 4 76 0 71 0 37 6 4 6 89 69 31...

Page 12: ...um Thickness mm Rockwell C Rockwell A Rockwell B Superficial 15N Superficial 30N Superficial 45N Superficial 15T Superficial 30T Superficial 45T 0 006 0 008 0 010 0 012 0 014 0 016 0 018 0 020 0 022 0...

Page 13: ...loys H 1 8 Carbide Ball 98 07 10 588 4 60 Aluminum zinc and lead K 1 8 Carbide Ball 98 07 10 1471 150 L Carbide Ball 98 07 10 588 4 60 M Carbide Ball 98 07 10 980 7 100 P Carbide Ball 98 07 10 1471 15...

Page 14: ...tructions Parts Manual Page 14 1 Load Unload Handle 2 Turn wheel 3 Lifting Screw Cover 4 Anvil 5 Indenter 6 Screws 7 Top cover 8 Screws 9 Rear cover 10 Indicator 11 Indenter Locking Screw 12 Weight Lo...

Page 15: ...Xi Li Haidian District Beijing 100192 China Tel 86 10 59792409 Fax 86 10 59814851 General E mail info phase2china com cn MEXICO Phase II de Mexico Calle A No 4 Promer Piso Col San Marcos Azcapotzalco...

Page 16: ...Operating Instructions Parts Manual Page 16 Digital Indicator Series 9500 Digital Indicators www phase2plus com...

Page 17: ...icators are an accurate yet affordable option to replace the dial on your analog hardness tester The 9500 series indicator gives you the complete functionality of a true digital machine with popular f...

Page 18: ...allation 1 Be sure that indicator has sufficient charge If the battery symbol is empty you should charge the indicator for approx 1 5 hours prior to use 2 Press the Power button to turn on The indicat...

Page 19: ...tion 1 Power the indicator on 2 There will be a value shown on the display This value must be set to ZERO by turning the fine adjustment on your hardness tester as shown in the picture below Fine Adju...

Page 20: ...old the hardness value the moment the reading is stable On softer metals the penetrator may continue to indent the material which may affect the reading The lock feature will prevent the value from ch...

Page 21: ...hown on the display after each test Once the set number of tests have been obtained the average and repeatability value will be shown on the display Statistics con t 1 Press the Menu Enter button Make...

Page 22: ...t that Press the Menu Enter button to save and return to the main test screen Memory Functions The 9500 series indicators can store up to 999 hardness values and can be viewed at your convenience by a...

Page 23: ...ntinues into the penetrator The indicator will soon Beep alerting you that its almost at the top Once the pre load is set the indicator will show either 2 80mm or 3 20mm depending upon the scale set a...

Page 24: ...dicator to automatically correct the measured value when the Lock feature is on If you highlight Enter this will allow you to set the calibration by manually entering in the value shown on the test bl...

Page 25: ...rings cables and connectors batteries diamond stylus contact probes etc Consumable wearable items such as cables and probes have a 90 day warranty from date of purchase This warranty is exclusive and...

Reviews: