11
Installation
Connecting to the
mains power supply
Permissible input voltage range:
• 100 ... 120 VAC (
±
10 %)
• 200 ... 240 VAC ( ± 10 %)
Fig. 5: Power supply pin assignment; Type: Harting Han 3A
The drive electronics ensures automatically the correct direction of rotation of the
pump.
Fuse protection
To protect the motor in case of malfunction, carry out fuse protection in accor-
dance with the regional regulations.
– Select a fuse with slow characteristics.
WARNING
Safe electrical installation
Safe operation after installation is the responsibility of the operator. The pump and its
electrical equipment have no lock-out/tag-out device and no emergency off device.
Make sure that the system is integrated in an emergency off safety circuit.
– If an emergency off situation is triggered, the voltage supply must be imme-
diately interrupted.
Consult Pfeiffer Vacuum for special requirements.
CAUTION
Excess voltage!
Danger of destroying the motor.
Power connections must comply with local regulations. Voltage and frequency infor-
mation given on the motor rating plate must correspond to the mains voltage and
frequency values.
To protect the motor and supply cable in case of malfunction, mains fuse protection
must be implemented.
1
Neutral conductor
2
Phase L1
3
not connected
4
earth, PE
1
2
3
4
Summary of Contents for Penta 10