background image

15

Tradename

Chemical name

Danger class

Precautions associated  Action if spillage or human 

Product name

(or Symbol)

with substance

contact

Manufacturer

1.

2.

3.

4.

5.

5. Legally Binding Declaration

I hereby declare that the information supplied on this form is complete and accurate. The despatch of equipment will be in
accordance with the appropriate regulations covering Packaging, Transportation and Labelling of Dangerous Substances.

Name of Organisation: _______________________________________________________________________________

Address:

_____________________________________

Post code: _____________________________________

Tel.: ______________________________________________________________________________________

Fax:

_____________________________________

Telex: ________________________________________

Name:  

______________________________________________________________________________________

Job title:

______________________________________________________________________________________

Date:

_____________________________________

Company stamp: ________________________________

Legally binding signature: _____________________________________________________________________________

Declaration of Contamination of Vacuum Equipment and Components

The repair and/or service of vacuum components will only be
carried out if a correctly completed declaration has been
submitted. Non-completion will result in delay. 

The manufacturer could refuse to accept any equipment
without a declaration.

This declaration can only be completed and signed by authorised and qualified staff:

1. Description of component:

- Equipment type/model: _________________________

- Code No.:

__________________________

- Serial No.:

__________________________

- Invoice No.:

__________________________

- Delivery Date:

__________________________

3. Equipment condition

- Has the equipment been used?

yes  

no 

- What type of pump oil was used?

___________________________________________

- Is the equipment free from potentially harmful

substances?

yes 

(go to section 5)

no 

(go to section 4)

4. Process related contamination

of equipment

- toxic

yes 

no 

- corrosive

yes 

no 

- microbiological hazard*)

yes 

no 

- explosive*)

yes 

no 

- radioactive*)

yes 

❐ 

no 

- other harmful substances yes 

no 

*) We will not accept delivery of any equipment that has been radioactively or microbiologically contaminated without written

evidence of decontamination!

2. Reason for return:

_____________________________________________

_____________________________________________

_____________________________________________

_____________________________________________

_____________________________________________

Please list all substances, gases and by-products which may have come into contact with the equipment:

Summary of Contents for MVP 006-4

Page 1: ...Diaphragm Pump PU 0034 BE B 0606 MVP 006 4 Betriebsanleitung Operating Instructions...

Page 2: ...The Pressure Side 6 3 4 Connecting To Power Supply 7 4 Operations 8 4 1 Important Information 8 4 2 Switching On The Pump 8 4 3 Select rotation speed control 8 4 4 Shutting Down The Pump 8 5 What To...

Page 3: ...instructions in the Service Section Due to the residual leak rate of the equipment there may be an exchange of gas albeit extremely slight between the environment and the vacuum system Adopt suitable...

Page 4: ...Pressure side Power supply connection Position numbers Identical components and accessories parts have the same position numbers in all illustrations Danger of damage to the pump or system CAUTION Da...

Page 5: ...d The pumping of gases which are contaminated with particles dust and condensate The Pump may not be used for the purpose of generating pressure The pumping of liquids Connection to pumps and units wh...

Page 6: ...between the vacuum system and pump as short as possible Ensure no mechanical forces act on the pump by a rigid piping system use elastic connections or bellows Connect pump with intake connection to...

Page 7: ...th pump base to frame potential as defined Stand alone operation with TPS 100 Connect power supply via connection cable PM 051 421 T with TPS 100 The pump starts immediately when the power unit is swi...

Page 8: ...alone operation In the the standalone operation mode the pump can be opera ted in two different modes High speed mode and Low speed mode To select the operating mode the DIP switch 2 on the control bo...

Page 9: ...at atmospheric pressure for condensate a few minutes Deposits have been formed Clean and inspect pump heads inside the pump Hose connectors between pump Check hose connectors between pump are leaky h...

Page 10: ...e dismantling Detach intake and exhaust line from the pump As far as possible place pump on its side so that the head to be dismantled points up Use open ended wrench SW 12 to remove fitting 10 1 at t...

Page 11: ...4 3 3 3 2 2 2 view B Ansicht A Ansicht B B 1 Dismantling the membrane heads 1 Membrane head 1 2 Membrane head 2 3 Membrane head 3 4 Membrane head 4 10 Interhead connection 10 1 Hose fitting 11 Crossh...

Page 12: ...nits which are contaminated microbiologically explo sively or radioactively cannot be accepted as a matter of principle Fill Out The Contamination Declaration In every case the Contamination Declarati...

Page 13: ...ssure mbar 1050 Permissible exhaust pressure mbar 1300 Leak rate mbar l s 6 10 2 Max operating altitude a s l m approx 1000 Ambient temperature range C 5 40 Emission sound pressure level at 1000 min 1...

Page 14: ...ch Come Into Contact With The Medium 1 TPS 100 Power supply unit for MVP 006 4 2 TPS 150 Power supply unit for MVP 006 4 TMH 071 TPD 011 Pos Description Pieces Size Number Comments Order Quantity Oper...

Page 15: ...he repair and or service of vacuum components will only be carried out if a correctly completed declaration has been submitted Non completion will result in delay The manufacturer could refuse to acce...

Page 16: ...WG entspricht We hereby certify that the product specified below is in accordance with the provision of EU Machinery Directive 98 37 EEC EU Electromagentic Compatibility Directive 89 336 EEC and EU Lo...

Page 17: ...17...

Page 18: ...9 0 64 41 8 02 2 02 info pfeiffer vacuum de www pfeiffer vacuum net Vacuum is nothing but everything to us Turbopumps Rotary vane pumps Roots pumps Dry compressing pumps Leak detectors Valves Componen...

Reviews: