12

7. Service 

Do Make Use Of Our Service Facilities

In the event that repairs are necessary to your pumping 
station, a number of options are available to you to ensure
any system down time is kept to a minimum:
– Have the pump repaired on the spot by our Pfeiffer

Vacuum Service Engineers;

– Return the individual components to the manufacturer for

repairs;

– Replace individual components with a new value

exchange units. 

Local Pfeiffer Vacuum representatives can provide full
details.

Before Returning:

When returning the pump please use original factory
packing.

Dismantle all accessories.

If the pump free of harmful substances, please attach a
clearly visible notice: “Free of contamination” (to the unit
being returned, the delivery note and accompanying
paperwork). 

Harmful substances" are substances and preparations as
defined in current legislation. Pfeiffer Vacuum will carry out
the decontamination and invoice this work to you if you have
not attached this note. This also applies where the operator
does not have the facilities to carry out the decontamination
work. Units which are contaminated microbiologically, explo-
sively or radioactively cannot be accepted as a matter of
principle.

Fill Out The Contamination Declaration

In every case the "Contamination Declaration" must be
completed diligently and truthfully.

A copy of the completed declaration must accompany the
unit; any additional copies must be sent to your local 
Pfeiffer Vacuum Service Center.

Please get in touch with your local Pfeiffer Vacuum represen-
tatives if there are any questions regarding contamination.

Decontaminate units before returning or possi-

ble disposal. Do not return any units which are
microbiologically, explosively or radio-
actively contaminated.

Returning Contaminated Units

If contaminated units have to be returned for
maintenance/repair, the following instructions concerning
shipping must be followed without fail:

Neutralise the pump by flushing with nitrogen or dry air.

Seal all openings to the air.

Seal pump or unit in suitable protective foil.

Ship units only in appropriate transport containers.

WARNING

Repair orders are carried out according to our
general conditions of sale and supply. 

If repairs are necessary, please send the unit together
with a short damage description to your nearest 
Pfeiffer Vacuum Service Center.

PLEASE NOTE

Summary of Contents for MVP 006-4

Page 1: ...Diaphragm Pump PU 0034 BE B 0606 MVP 006 4 Betriebsanleitung Operating Instructions...

Page 2: ...The Pressure Side 6 3 4 Connecting To Power Supply 7 4 Operations 8 4 1 Important Information 8 4 2 Switching On The Pump 8 4 3 Select rotation speed control 8 4 4 Shutting Down The Pump 8 5 What To...

Page 3: ...instructions in the Service Section Due to the residual leak rate of the equipment there may be an exchange of gas albeit extremely slight between the environment and the vacuum system Adopt suitable...

Page 4: ...Pressure side Power supply connection Position numbers Identical components and accessories parts have the same position numbers in all illustrations Danger of damage to the pump or system CAUTION Da...

Page 5: ...d The pumping of gases which are contaminated with particles dust and condensate The Pump may not be used for the purpose of generating pressure The pumping of liquids Connection to pumps and units wh...

Page 6: ...between the vacuum system and pump as short as possible Ensure no mechanical forces act on the pump by a rigid piping system use elastic connections or bellows Connect pump with intake connection to...

Page 7: ...th pump base to frame potential as defined Stand alone operation with TPS 100 Connect power supply via connection cable PM 051 421 T with TPS 100 The pump starts immediately when the power unit is swi...

Page 8: ...alone operation In the the standalone operation mode the pump can be opera ted in two different modes High speed mode and Low speed mode To select the operating mode the DIP switch 2 on the control bo...

Page 9: ...at atmospheric pressure for condensate a few minutes Deposits have been formed Clean and inspect pump heads inside the pump Hose connectors between pump Check hose connectors between pump are leaky h...

Page 10: ...e dismantling Detach intake and exhaust line from the pump As far as possible place pump on its side so that the head to be dismantled points up Use open ended wrench SW 12 to remove fitting 10 1 at t...

Page 11: ...4 3 3 3 2 2 2 view B Ansicht A Ansicht B B 1 Dismantling the membrane heads 1 Membrane head 1 2 Membrane head 2 3 Membrane head 3 4 Membrane head 4 10 Interhead connection 10 1 Hose fitting 11 Crossh...

Page 12: ...nits which are contaminated microbiologically explo sively or radioactively cannot be accepted as a matter of principle Fill Out The Contamination Declaration In every case the Contamination Declarati...

Page 13: ...ssure mbar 1050 Permissible exhaust pressure mbar 1300 Leak rate mbar l s 6 10 2 Max operating altitude a s l m approx 1000 Ambient temperature range C 5 40 Emission sound pressure level at 1000 min 1...

Page 14: ...ch Come Into Contact With The Medium 1 TPS 100 Power supply unit for MVP 006 4 2 TPS 150 Power supply unit for MVP 006 4 TMH 071 TPD 011 Pos Description Pieces Size Number Comments Order Quantity Oper...

Page 15: ...he repair and or service of vacuum components will only be carried out if a correctly completed declaration has been submitted Non completion will result in delay The manufacturer could refuse to acce...

Page 16: ...WG entspricht We hereby certify that the product specified below is in accordance with the provision of EU Machinery Directive 98 37 EEC EU Electromagentic Compatibility Directive 89 336 EEC and EU Lo...

Page 17: ...17...

Page 18: ...9 0 64 41 8 02 2 02 info pfeiffer vacuum de www pfeiffer vacuum net Vacuum is nothing but everything to us Turbopumps Rotary vane pumps Roots pumps Dry compressing pumps Leak detectors Valves Componen...

Reviews: