Input
43
10
.02
List of parameters for control P320 / P321
The operator has free access to the "
100
" parameters.
Parameters "
2
00" - "800" can only be changed after entering a code number
and many only be changed by authorised personnel.
Group
P
arameter
Description
S
et
ting range
S
et value
1
101
Pedal controlled start backtack
(I = OFF, II = ON)
I - II
I
102
Reverse rotation (I = OFF, II = ON)
I - II
I
103
Placed stitch (I = OFF, II = ON)
I - II
I
104
Bobbin thread monitoring
(0 = Off, 1 = Counter)
0 - 1
1
105
Bobbin thread counter (2500 ME PREMIUM only)
0 - 99999
12000
106
Bobbin thread remaining counter
(2500 ME PREMIUM only)
0 - 999
100
107
Stitch length adjustment (2500 ME PLUS only)
-0,2 - +0,2 mm
0
108
Display main processer software version
109
Display step motor processor software version
110
Display control panel software version
111
Display sewing drive component software
version
112
Control panel key tone (2500 PREMIUM only),
(I = OFF, II = ON)
I - II
II
113
Control panel key tone when moving from
one area to another (2500 PREMIUM only),
(I = OFF, II = ON)
I - II
I
116
Display serial number of machine
-
-
2
201
Machine confi guration
8 = 2571, 2591,
9 = 2571, 2591 with photo cell,
10 = reserved,
11 = reserved,
12 = 2574
13 = 2574 with photo cell
8 - 14
8
Summary of Contents for POWERLINE 2571 ME PLUS