Technical data
8.1
Safety Ratings
Type designation
VersiComb II
230-3
400-5.5
480-5,5
230-4
400-7.5
480-7,5
230-5,5
400-11
480-11
230-7.5
400-15
480-15
Mains / Motor voltage
acc. to DIN EN 50160 (IEC 38)
3AC 230V ± 10% 50/60Hz
3AC 400V ± 10% 50/60Hz
3AC 480V ± 10% 50/60Hz
Rated device current Starting section
12A
15A
25A
32A
Rated device current Braking section
25A
35A
45A
55A
Motor rating at 400V
5.5kW
7.5kW
11kW
15kW
min. Motor load
40% of the device rating
Starting time
0.5 … 16s
Starting torque
0 … 80%
Braking voltage
0 … 230V at 230V
0 … 400V at 400V
0 … 480V at 480V
max. Braking time
10s
Delay for reduction of residual e.m.f.
self-optimizing (100 … 1500ms)
max. Switching frequency
with a starting time and braking time
up to 10s each
30/h
30/h
30/h
20/h
max. Cross-sectional area for connect.
(Tightening torque of terminals)
Control terminals 2.5mm² (0.5 - 0.6 Nm)
Power terminals 4mm² flexible; 6mm² rigid (0.5 - 0.6 Nm)
I²t-values of power semiconductors,
Starting section
1350A²s
6050A²s
7200A²s
7200A²s
I²t-values of power semiconductors,
Braking section
1350A²s
1350A²s
6050A²s
7200A²s
Contact rating of output relays
3A/250V AC
Weight
1.5 kg
Performance Level (EN ISO 13849-1)
PL b
Category (EN ISO 13849-1)
B
PFH
[ 1/h ]
4,23E-06
MTTFd
[ years]
100