![PESA RCP-CSD Manual Download Page 33](http://html1.mh-extra.com/html/pesa/rcp-csd/rcp-csd_manual_1531769033.webp)
RCP-CSD
Chapter 3 – Operation
25
Multi-Bus Gang Mode – Follow Switch
Multi-bus Gang mode allows follow switches to be taken on multiple destinations at the same time. To
perform a follow switch in Multi-Bus Gang mode, first the destinations are selected, then a source is
selected, then the switch is taken on all levels.
To enter Multi-Bus Gang mode from any other mode, press ALL LEVELS / GANG LEVELS for at least
one second.
When in Multi-Bus Gang mode, the display will show
MULTI-BUS
in the Mode field as shown in Figure
12, and the ALL LEVELS / GANG LEVELS key led will be flashing.
PRESET
SOURCE
MULTI-BUS
PAGE 1
DESTINATION
DESTINATION
DESTINATION
DESTINATION
SOURCE
SOURCE
SOURCE
SOURCE
DESTINATION
DESTINATION
DESTINATION
DESTINATION
SOURCE
SOURCE
SOURCE
SOURCE
Figure 12. Multi-Bus Gang Mode – Follow Switch Display
To take a follow switch in Multi-Bus gang mode:
1.
Use PAGE UP, PAGE DOWN, and the Display Panel keys to select the destinations.
2.
Select the source by using Data keys, PRESET / COPY (see page 23), or PREV and NEXT to
scroll through all the sources in the Source Include List. The source will be displayed in the
Selection field. If the source displayed is blinking, it is not a valid source. Press CLEAR / STORE
to clear a source from the Selection field.
3.
Press TAKE / CHOP to take the switch. The Data field pairs will remain in inverse video, and
current status will be displayed.
Multi-Bus Gang Mode – Breakaway Switch
Breakaway switches cannot be performed in Multi-Bus Gang mode.