4-4
Section 4
Electrical System
DC235
Aft Bilge
Press to activate the manual pump.
Fresh Water
Press to activate the fresh water pump.
Washdown
Press to activate the raw water washdown
pump. The pump is a pressure demand type
and is protected by a circuit breaker on the
MDP and an automatic reset breaker in the
pump motor.
Livewell
Press to activate the livewell circulation
pump to supply water to the livewell. The
pump is protected by a circuit breaker on the
helm panel and an automatic reset breaker
in the pump motor.
ACC
This is an open switch and reserved for
future additional accessories. DO NOT
exceed 10 amps.
Power Steering (Optional)
Press to activate the power steering feature.
4.5 Electrical System
Maintenance
12-Volt DC Electrical System
Maintenance
Semi-annually spray all exposed electrical
components behind the helm and in the
plugs with a protector specific for electrical
connections.
Make sure to check that all below deck wir-
ing is properly supported, the insulation is
sound and there are no loose or corroded
terminals. Clean any corroded terminals
thoroughly with sandpaper, or replace them.
Tighten securely and spray with a metal and
electrical protector. Inspect all engine wiring.
Check the electrolyte level in the batteries
regularly and add distilled water as neces-
sary. If the batteries are frequently charged
by a battery charger, check the electrolyte
level more often. The correct fluid level in the
cells is approximately ¼ to ½ inch above the
plates. If fluid is needed, fill to the proper
level with distilled water ONLY. DO NOT
overfill. Some batteries are sealed and can-
not be filled.
Keep the tops of any battery clean and dry.
Dirt and water can conduct electricity from
one post to the other and can cause battery
discharge or cause errant engine warnings.
Keep the battery posts free of corrosion. DO
NOT use wing nuts to attach battery cables.
Remove the cables and clean the posts and
cable clamps with a battery post cleaner or
sandpaper as required. Coating the battery
posts and cable clamps with petroleum jelly
or silicone grease will help protect and
reduce corrosion. Battery cables, both posi-
tive and ground must be replaced when they
show signs of corrosion or fraying. Deterio-
rated cables cause a considerable voltage
loss when high currents are drawn, as for
starting the engine.
NOTICE
Under water lights are designed to be
used only when in the water. Leaving
them on when out of the water can
cause permanent damage to the
lights.
!
DANGER
FIRE OR EXPLOSION HAZARD
Explosion or fire from hydrogen gases
produced by lead acid batteries will
cause death or serious injury. DO NOT
smoke or bring a flame near battery
storage area. If ignited by a spark or
flame, gas may explode violently,
causing spraying of battery acid or
fragmentation of the battery.
Summary of Contents for DC 235 DUAL CONSOLE
Page 1: ...OWNER S MANUAL MARCH 2017...
Page 2: ...U S Patents 8 113 137 Other patents pending...
Page 4: ......
Page 10: ...Operator Notes 6 DC235...
Page 20: ...Operator Notes 2 6 DC235...
Page 34: ...5 6 Operator Notes DC235...
Page 36: ...6 2 Operator Notes DC235...
Page 42: ...8 2 Operator Notes DC235...
Page 50: ...Operator Notes 9 8 DC235...
Page 78: ...Operator Notes A 6 DC235...
Page 80: ...Appendix B Maintenance Log Date Hours Dealer Service Repairs B 2 DC235 Maintenance Log...
Page 81: ...Maintenance Log B 3 Appendix B DC235 Date Hours Dealer Service Repairs...
Page 82: ...Appendix B Maintenance Log Date Hours Dealer Service Repairs B 4 DC235...
Page 83: ...Boating Accident Report C 1 Appendix C DC265 Boating Accident Report...
Page 84: ...C 2 Appendix C Boating Accident Report DC265...
Page 85: ...Float Plan D 1 Appendix D DC235 Float Plan...
Page 86: ...Operator Notes D 2 DC235...
Page 90: ...Operator Notes E 4 DC235...
Page 91: ...Schematics F 1 Appendix F DC235 Schematics 0DVWHU LVWULEXWLRQ 3DQHO...
Page 92: ...F 2 Appendix F Schematics DC235 0 3 5HYHUVH 6LGH...
Page 93: ...Schematics F 3 Appendix F DC235...
Page 94: ...F 4 Appendix F Schematics DC235 0DLQ HOP 6ZLWFK 3DQHO...
Page 95: ...Schematics F 5 Appendix F DC235 0DLQ HOP 6ZLWFK 3DQHO...
Page 96: ...F 6 Appendix F Schematics DC235...
Page 99: ...Schematics F 9 Appendix F DC235...
Page 102: ...F 12 Appendix F Schematics DC235...
Page 108: ...F 18 Appendix F Schematics DC235...
Page 114: ...Operator Notes F 24 DC235...
Page 119: ......
Page 120: ......