Standard
Standard
To Be
Allowable
Inspection items
Dimension
Value
Repaired
Limit
Remarks
VALVE (Continued)
Inlet valve
Open-BeforeTD.C.
13°
timing
Close-After B.D.C.
43°
Exhaust valve
Open-Before B.D.C.
43°
timing
Close-AfterTD.C.
13°
PUSH ROD
Overall length
146
145.6-146.4
(5.748")
(5.732-5.764")
Outer diameter
6.3
(.248")
ROCKER ARM
Wear, rocker arm shaft
11.66
11.65-11.67
11.57
(.459")
(.4587-.4594")
(.4555")
Clearance between rocker arm and
0.032-0.068
0.2
Oil clearance
shaft
(.0013-.0027")
(.008")
LUBRICATION SYSTEM
OIL PUMP
Oil pressure switch operating pressure
0.3
0.2-0.4
(kg/cm
2
) (psi)
(4.27)
(2.844-5.688)
Relief pressure (kg/cm
2
) (psi)
3-5
(42.66-71.1)
Lubrication oil capacity (lit)
3.0
Tip clearance (rotor-to-vane)
0.02-0.15
0.25
(.0008-.006")
(.010")
Side clearance (rotor-to-cover)
0.1-0.15
0.2
(.004-_006")
(.008")
FUEL SYSTEM
INJECTION PUMP
Type
131017390
Diameter of plunger
4.5
(.177")
Stroke of plunger
6
BeforeTD.C.
27.0-29.0°
Injection timing
Piston movement
4.573-5.251
beforeTD.C.
(.1800-.2067')