43
PFA SERIES INSTALLATION, OPERATION, MAINTENANCE
OPERATION TESTS (for service personnel)
► FANS
• Use the arrow keys to turn fans on and off [note: oil temperature must
be below 122ºF (50ºC)]
• Monitor rpm and current values of each fan
► INTERLOCKS
• To view interlocks and if they’re open or closed
•
= open, = closed
► BASKET
• Use the arrow keys to move basket up and down
• Monitor current values of motor
► DRAWER
• Use the arrow keys to move drawer in and out
• Monitor current values of motor
► HEATER
• For factory heater calibration.
Do not adjust
.
► DISPLAY
• Use START and CANCEL to turn all the pixels of the LCD on and off
► CIRCUIT BOARD
• Monitor the circuit board temperature
OPERATION TESTS
FANS
INTERLOCKS
BASKET
DRAWER
HEATER
<MORE >
START TO SELECT
PRESET COUNTERS
DISPLAY
CIRCUIT BOARD
<MORE >
START TO SELECT
SET DEFAULTS
• Press start to reset options and presets to factory defaults
• PRESETS and UNITS will not change
SET DEFAULTS
PRESS START TO RESET
OPTIONS AND PRESETS
TO FACTORY DEFAULTS
OPTION CHANGES
Example °F to °C)
DISPLAY READS
OPERATOR ACTION
DISPLAY NOW READS
OPERATOR OPTIONS
WAIT MODE
STANDBY MODE
PRESET MODE
BUZZER VOLUME
KEY VOLUME
<MORE >
START TO SELECT
9
4
1) From OPERATION OPTIONS
menu, scroll down to UNITS
using key
2) Press
START
OPERATOR OPTIONS
UNITS
DRAIN TIME
COOK TEMP
STANDBY TEMP
LCD CONTRAST
<MORE >
START TO SELECT
º
C
15S
350
º
F
275
º
F
5
Note: All OPERATION OPTIONS menu items can be customized by following this basic procedure (some use the arrow
keys).