PFA SERIES INSTALLATION, OPERATION, MAINTENANCE
22
PERIODIC MAINTENANCE
Air Filter Cartridge Replacement
•
Replace the air filter cartridge at least once every 2 months, more often
for higher volume usage. Replacement is safer and easier when the fryer
is cool rather than hot.
•
Only PERFECT FRY filters may be used in your Perfect Fry unit.
Steps to replace air filter cartridge
1. Open front panel by lifting and turning latches
2.
Release latch on air filter cage, and remove air filter cage and air filter car
-
tridge from filter compartment
3.
Remove old used air filter cartridge from air filter cage.
4.
Wipe air filter cage clean.
5.
Fit air filter cage over new air filter cartridge and write date on cartridge.
(↑↑ Arrows up)
6.
Install air filter cage and new air filter cartridge firmly back into filter com
-
partment and latch in place.
7. Close front panel and latch shut.
PFS Automatic Extinguisher
• The PFS automatic extinguisher must be inspected monthly by the
owner/operator and semi-annually by authorized service personnel as
per NFPA 17A. It is important that a maintenance program is set up with
a local fire service company to ensure that local jurisdictional codes are
being met. Please refer to PFS Automatic Extinguisher section of this
manual for more information.