background image

1

WARNING

DO NOT

 store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

DO NOT

 use an extension cord or an adapter plug; avoid fire hazard or electric shock. Do not remove any prong 

from the power cord..

Be sure the electrical service is adequate for the model you have chosen. This information can be found on the 

serial plate, which is located on the side of the cabinet and behind the grille.

Be sure the air conditioner is properly grounded. To minimize shock or fire hazards, proper grounding is import-

ant. The power cord is equipped with a three-prong grounding plug for protection against shock hazards.

Your air conditioner must be used in a properly grounded wall receptacle. If the wall receptacle you intend to 

use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician 

install the proper receptacle.

Ensure the receptacle is accessible after the unit installation.

READ SAFETY PRECAUTIONS BEFORE INSTALLATION

To prevent injury to the user or other people and property damage, the following instructions must be followed.  

Incorrect operation due to ignoring of instructions may cause harm or damage. 

NEVER DO THIS.

ALWAYS DO THIS.

SAFETY PRECAUTIONS

CAUTION

•  Contact a qualified installer for installation of this unit if necessary.
•  Contact a qualified service technician for repair or maintenance of this unit.
•  The air conditioner is not intended for use by young children without supervision. Young children should be supervised 

to ensure that they do not play with the air conditioner.

•  If the power cord is to be replaced, replacement work should be performed by authorized personnel only.
•  Installation and repair work must be performed in accordance with the national wiring standards by authorized 

personnel only.

• 

DO NOT

 operate your air conditioner in a wet room such as a bathroom or laundry room.

•  This appliance can be used by persons with reduced physical, sensory or mental capabilities or lack of experience 

and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and 

understand the hazards involved. Cleaning and user maintenance shall not be made by children without supervision.

•  Children should be supervised to ensure that they do not play with the appliance. 
•  Disabled persons may require assistance with setup and/or use.
• 

DO NOT

 operate the appliance with a damaged cord or plug. Call Consumer Services at 844-472-2473 if the power 

supply cord and/or plug is damaged; it must be replaced by a qualified service technician in order to avoid a hazard.

•  Prior to cleaning or other maintenance, the appliance must be disconnected from its main power supply.
• 

DO NOT

 install the appliance in a location that may be exposed to combustible gas.

•  If combustible gas (or other flammable liquids or vapors) accumulates around the unit, it may cause fire.
•  

DO NOT

 run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord 

under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.

•  To reduce the risk of fire or electric shock, do not use the appliance with any solid-state speed control device.
•  The appliance shall be installed in accordance with national wiring regulations.
•  When there are differences between “USER MANUAL” and “Remote Control Manual” on function description, the 

description on “USER MANUAL “ shall prevail.

Summary of Contents for PORT10000A

Page 1: ...RTABLE AIR CONDITIONER FOR MODELS PORT8000A PORT10000A PORT12000A Before using your air conditioner please read this manual carefully and keep it for future reference along with your receipt USER MANU...

Page 2: ...___________________________ Purchase Date _____________________________________ Store Purchased ______________________________________ Installation Date ____________________________________ Installati...

Page 3: ...s manual ENERGY SAVING TIPS Use the unit in the recommended room size Locate the unit where furniture cannot obstruct the air flow Keep blinds curtains closed during the sunniest part of the day cooli...

Page 4: ...replacement work should be performed by authorized personnel only Installation and repair work must be performed in accordance with the national wiring standards by authorized personnel only DO NOT op...

Page 5: ...Do not place your air conditioner where it can fall or be pulled into water or any other liquid If the unit does ever fall into water unplug it immediately DO NOT install the unit in a location that m...

Page 6: ...orten window adapter for narrow windows PART DESCRIPTION QUANTITY Unit Adapter 1 pc Exhaust Hose 1 pc Window slider Adapter 1 pc Bolt 1 pc Window Slider A 1 pc Window Slider B 1 pc Foam Seal A Adhesiv...

Page 7: ...utlet ABOUT FLUORINATED GASES This air conditioning unit is a hermetically sealed unit that contains fluorinated gases For specific information on the type of gas and the amount please refer to the re...

Page 8: ...nd horizontal window applications However it may be necessary for you to improvise or modify some aspects of the installation procedures for certain types of windows Please refer to Fig 5 and Fig 6 fo...

Page 9: ...the hose Make sure that there are no obstacles around the air outlet of the exhaust hose 20 inch clearance in order to ensure the exhaust system works properly Fig 11 Once the Exhaust Hose assembly is...

Page 10: ...he glass and the window frame to prevent air and insects from getting into the room STEP 4 Fig 15 If desired install the security bracket with 2 screws as shown STEP 5 Fig 16 Insert the window slider...

Page 11: ...the glass and the window frame to prevent air and insects from getting into the room STEP 4 Fig 20 If desired install the security bracket with 2 screws as shown STEP 5 Fig 21 Insert the window slider...

Page 12: ...s in a cool dark place Exposure to direct sunshine or extreme heat can shorten the lifespan of the unit When the water level of the bottom tray reaches a predetermined level the unit beeps 8 times and...

Page 13: ...In households with animals you will have to periodically wipe down the grille and clean the air filter to prevent blocked airflow due to animal hair CLEANING THE UNIT Use a lint free cloth soaked with...

Page 14: ...C increments in a range of 62 F 17 C to 86 F 30 C NOTE The control is capable of displaying the temperature in degrees Fahrenheit or degrees Celsius To convert from one to the other press and hold the...

Page 15: ...inutes This new temperature will be maintained for 7 hours before it returns to the originally selected temperature This ends the SLEEP mode and the unit will continue to operate as originally program...

Page 16: ...in If error repeats call Consumer Services E2 Evaporator Temperature Sensor Error Unplug the unit and plug it back in If error repeats call Consumer Services E3 Condenser Temperature Sensor Error Unpl...

Page 17: ...o defrost the coil set to FAN only mode Air filter may be dirty Clean filter Refer to Care and Cleaning section To defrost set to FAN only mode Thermostat is set too cold for night time cooling To def...

Page 18: ......

Page 19: ......

Page 20: ...5151 Belt Line Rd Suite 878 Dallas TX 75254 Distributed by 844 4PA AIRE 844 472 2473 www perfectaire us Specification and performance data is subject to change without notice Printed in China PA User...