background image

12

OPERATING INSTRUCTIONS

NOTE: 

Fan speeds, SLEEP mode, and FOLLOW ME 

feature can only be adjusted with the remote control.

NOTE:

 When selecting a mode on the unit’s display, 

fan speed cannot be selected. The fan speed goes to 

“auto” by default.

 COOL mode

•  Press the “MODE” button until the “COOL” 

indicator light comes on.

•  Press the “+” or “-” button to select your desired 

room temperature. The temperature can be set 

within a range of 62°F~86°F/17°C~30°C.

•  Press the “FAN SPEED” button on the remote 

control to choose the fan speed.

 FAN mode

•  Press the “MODE” button until the”FAN “ indicator 

light illuminates.

•  Press the “FAN SPEED” button on the remote 

control to choose the fan speed. The temperature 

cannot be adjusted.

•  Remove exhaust hose and slider.

 DRY mode

•  Press the “MODE” button until the “DRY” indicator 

light comes on.

•  Under this mode, you cannot select a fan speed or 

adjust the temperature. The fan motor operates at 

LOW speed only.

•  Keep windows and doors closed for the best 

dehumidifying effect.

•  Remove exhaust hose and slider when in this 

mode.

 SLEEP/ECO mode

NOTE: 

This feature can be activated from the remote 

control ONLY.
To activate SLEEP feature, the set temperature 

will increase by 2°F(1°C) in 30 minutes. The set 

temperature will then increase by another 2°F(1°C) 

after an additional 30 minutes. This new temperature 

will be maintained for 7 hours before it returns to 

the originally selected temperature. This ends the 

SLEEP mode and the unit will continue to operate as 

originally programmed.

NOTE: 

This feature is unavailable under FAN or  

DRY mode.

 FOLLOW ME feature

NOTE: 

This feature can be activated from the remote 

control ONLY.
The remote control serves as a remote thermostat 

allowing for the precise temperature control at its 

location. To activate the FOLLOW ME feature, point 

the remote control toward the unit and press the 

FOLLOW ME button. The remote displays the actual 

temperature at its location. The remote control will 

send this signal to the air conditioner in 3 minute 

intervals until the FOLLOW ME button is pressed 

again. If the unit does not receive the FOLLOW ME 

signal during any 7 minute span, the unit will beep to 

indicate the FOLLOW ME mode has ended.

 Auto-Restart

If the unit breaks off unexpectedly due to the power 

being cut, it will automatically restart with the 

previous function setting when the power resumes.

*WAIT 3 MINUTES BEFORE RESUMING OPERATION. 

Operation will automatically start after 3 minutes (once 

the unit is powered on). This is to protect the unit.

 Air Flow Direction Adjustment

•  Adjust the air flow direction manually by using the 

tab to move the louvers up or down.

•  Do not place any heavy objects or other loads on 

the louver; doing so will cause damage to the unit.

•  Keep the louver fully opened during all operations.

Summary of Contents for PORT10000A

Page 1: ...RTABLE AIR CONDITIONER FOR MODELS PORT8000A PORT10000A PORT12000A Before using your air conditioner please read this manual carefully and keep it for future reference along with your receipt USER MANU...

Page 2: ...___________________________ Purchase Date _____________________________________ Store Purchased ______________________________________ Installation Date ____________________________________ Installati...

Page 3: ...s manual ENERGY SAVING TIPS Use the unit in the recommended room size Locate the unit where furniture cannot obstruct the air flow Keep blinds curtains closed during the sunniest part of the day cooli...

Page 4: ...replacement work should be performed by authorized personnel only Installation and repair work must be performed in accordance with the national wiring standards by authorized personnel only DO NOT op...

Page 5: ...Do not place your air conditioner where it can fall or be pulled into water or any other liquid If the unit does ever fall into water unplug it immediately DO NOT install the unit in a location that m...

Page 6: ...orten window adapter for narrow windows PART DESCRIPTION QUANTITY Unit Adapter 1 pc Exhaust Hose 1 pc Window slider Adapter 1 pc Bolt 1 pc Window Slider A 1 pc Window Slider B 1 pc Foam Seal A Adhesiv...

Page 7: ...utlet ABOUT FLUORINATED GASES This air conditioning unit is a hermetically sealed unit that contains fluorinated gases For specific information on the type of gas and the amount please refer to the re...

Page 8: ...nd horizontal window applications However it may be necessary for you to improvise or modify some aspects of the installation procedures for certain types of windows Please refer to Fig 5 and Fig 6 fo...

Page 9: ...the hose Make sure that there are no obstacles around the air outlet of the exhaust hose 20 inch clearance in order to ensure the exhaust system works properly Fig 11 Once the Exhaust Hose assembly is...

Page 10: ...he glass and the window frame to prevent air and insects from getting into the room STEP 4 Fig 15 If desired install the security bracket with 2 screws as shown STEP 5 Fig 16 Insert the window slider...

Page 11: ...the glass and the window frame to prevent air and insects from getting into the room STEP 4 Fig 20 If desired install the security bracket with 2 screws as shown STEP 5 Fig 21 Insert the window slider...

Page 12: ...s in a cool dark place Exposure to direct sunshine or extreme heat can shorten the lifespan of the unit When the water level of the bottom tray reaches a predetermined level the unit beeps 8 times and...

Page 13: ...In households with animals you will have to periodically wipe down the grille and clean the air filter to prevent blocked airflow due to animal hair CLEANING THE UNIT Use a lint free cloth soaked with...

Page 14: ...C increments in a range of 62 F 17 C to 86 F 30 C NOTE The control is capable of displaying the temperature in degrees Fahrenheit or degrees Celsius To convert from one to the other press and hold the...

Page 15: ...inutes This new temperature will be maintained for 7 hours before it returns to the originally selected temperature This ends the SLEEP mode and the unit will continue to operate as originally program...

Page 16: ...in If error repeats call Consumer Services E2 Evaporator Temperature Sensor Error Unplug the unit and plug it back in If error repeats call Consumer Services E3 Condenser Temperature Sensor Error Unpl...

Page 17: ...o defrost the coil set to FAN only mode Air filter may be dirty Clean filter Refer to Care and Cleaning section To defrost set to FAN only mode Thermostat is set too cold for night time cooling To def...