Assembly and Operation Manual
9.3 Operating modes of the turnstile in potential
control mode
See Table 3 for the operating modes set from the RC panel. Setting the operating modes
for each direction is independent, i.e. setting the operating mode for one direction does not
change the operating mode set earlier for the opposite one.
Table 3. Potential control mode (the jumper is taken off from the J1 connector)
№
The turnstile
operating
modes
Levels on the
contacts should
be provided
Indication
on the RC
panel
Indication
on the LED
display
Turnstile status
1
Both directions
are locked (the
turnstile is
locked both for
entry and exit)
The high level —
on contacts
“Unlock A” and
“Unlock B” or low
level — on the
contact Stop
The red
indicator
above the
STOP
button
is on
The “Red
cross”
pictogram is
on
The turnstile is locked
2
One of the
passage
directions is
open (the
turnstile is open
for passage in
the set
direction)
The low level — on
the contact
corresponding to
the passage
direction, the high
levels — on the
other contacts
The green
indicator
above the
button of the
chosen
passage
direction is on
The “Green
arrow”
pictogram,
showing the
passage
direction is
on
If by the moment of
passage through the
turnstile the low level is
present on the contact,
corresponding to the set
passage direction, the
turnstile remains open in
the set direction
3
Both passage
directions are
open (the
turnstile is open
for passage in
both directions)
The low levels —
are on the contacts
corresponding to
the both directions,
the high level — on
the contact Stop
The two
green
indicators
(left and right)
are on
The two
“Green
arrow”
pictograms
(left and
right) are on
If by the moment of
passage through the
turnstile the low level is
present on the contact,
corresponding to the set
passage direction, the
turnstile remains open in
the set direction
For the ACS outputs note the following:
High level — contacts of the output relay are broken or the output transistor is
closed
Low level — contacts of the output relay are closed or the output transistor is open.
9.4 Actions in emergency
For urgent evacuation of people from business facilities in case of fire, natural calamities
and other emergencies, the additional emergency exit should be provided. Such
emergency exit can be the automatic anti-panic rotary section PERCo-BH02.
The additional emergency exit can be provided by the turnstile passage area. Construction
of the turnstile enables immediate clear of passage way without use of any special keys or
tools. By putting the
Fire
Alarm
signal to turnstile logic board the barrier arm automatically
falls down allowing the free exit (see Clause 5.10). The arm also drops down automatically
at a power supply loss.
24