CT/L-14 Controller
7
•
XP4
– power indicator connector on the controller housing;
•
XP5.1
,
XP5.2
–
XP8.1
,
XP8.2
– connectors (in pairs) to select the type of connected lock (see
Sect. 8.2.2):
−
jumpers are removed – standard electromechanical or electromagnetic lock is to be
connected to the corresponding output,
−
jumpers are installed – locks of
LB
- or
LBP
-series are without installed door sensor (reed
switch). The controller traces the passage on condition of the contact group of the lock.
Table 1. Lower board terminal blocks designation
Contact Contact name in the
Web-interface
Designation
XT1 (IN)
connector
IN1
In 1
“Door sensor #1” or “Input for PASS A signal from the turnstile #1”
GND
–
“Common”
IN2
In 2
“Door sensor #2” or “Input for PASS B signal from the turnstile #1”
or “Additional input IN #2”
IN3
In 3
“Door sensor #3” or “Input for PASS A signal from the turnstile #2”
or “Additional input IN #3”
GND
–
“Common”
IN4
In 4
“Door sensor #4” or “Input for PASS B signal from the turnstile #2”
or “Additional input IN #4”
IN5
In 5
“Additional input IN #5”
GND
–
“Common”
IN6
In 6
“Additional input IN #6”
XT2
(RC1)
connector
FA
FA
“Input for emergency unlocking (passage opening)
Fire alarm
”
GND
–
“Common”
DUA
DUA 1
“Control input of the OD1 from the RC-button” or “Control input of
direction A from the RC-panel #1”
DUSt
DUSt 1
“Input STOP from the RC-panel #1” or “Additional input IN #8”
DUB
DUB 1
“Control input of the OD2 from the RC-button” or “Control input of
direction B from the RC-panel #1” or “Additional input IN #9”
LdA
LdA 1
“Output for indication of direction A on the RC-panel #1”
LdSt
LdSt 1
“Output for indication STOP on the RC-panel #1”
LdB
LdB 1
“Output for indication of direction B on the RC-panel #1”
XT3 (OC)
connector
OC3
OK3
“Additional output OUT #7 (open collector)”
OC2
OK2
“Additional output OUT #6 (open collector)”
OC1
OK1
“Additional output OUT #5 (open collector)”
+12V
–
“Output of +12VDC power for outputs
OC1, OC2
and
OC3”
XT4 (+12VDC)
connector
+12V
–
“Input of cont 12VDC power from external PS”
GND
–
XT5 (RS-485)
connector
+12V
–
“Output of +12VDC power for
readers”
GND
–
A
–
“Connection of line A via RS-485”
B
–
“Connection of line B via RS-485”
XT6 (OUT1)
connector
NO1
NO1/C1/NC1
normally open contact
“Relay control output OD #1”
C1
central contact
NC1
normally closed contact