10  UPDATE OF EMBEDDED SOFTWARE 

Update  the  embedded software and format the memory is possible using the controller  Web-

interface in the 

Diagnostic 

section

 

(Appendix 4, p.9)

11  OPERATION 

When operating the controller, follow the safety measures indicated in Sect. 7.2. 
After the configuration, the controller can operate in the following modes: 

Without connection to the security system server. 

If connection to 

Ethernet

  network and PC is also unavailable, the controller can perform the 

following functions: 

  Reads identifiers of the presented cards sent from the reader, and grants or denies access, 

depending on their presence in the list. 

  Controls connected ODs. 

  Arms and disarms the protected zone; controls alarm line and ODs in “

Security”

  mode; 

activates additional outputs in “

Alarm”

 mode. 

  Records events in the event log in the controller memory. 

  Supports functions of local location monitoring, T&A and double-check access. 

If the controller is connected to the network and other controllers of the system, the function of 

global location monitoring is available. 

When connected to the security system server.  

Besides those that are supported in the stand-alone mode, the following functions are available: 

  Data from event log are automatically transferred to the database on security system server. 

  Availability of verification function depends on installed extensions of network software. 

11.1  ACS operating modes 

The change of operating mode is carried out by the command of software or Web-interface. 

 

Note: 

  In configuration “

Controller for one two-way lock

” and “

Controller for vehicle 

checkpoint

” should be made simultaneously for both directions. 

  Operating  mode in “

Controller for turnstile

”  configuration versions is  to be set 

independently for each direction 

The following ACM are provided by the controller, that operates as a part of ACS, (ACM indication 

is given in the Table 4): 

Open”

 operating mode – free passage mode. 

  OD remains unlocked until the operating mode is changed. 

  Pressing the buttons of RC-panel and RC-button (“

Exit

”) is ignored.  

 “

Control” 

operating mode –

 

basic operating mode as a part of ACS. 

  OD is locked. 

  When an access granting card is presented to the reader, OD is unlocked for 

Holding in 

unlocked state period

 “

Closed” 

operating mode –passage denial mode. 

  OD remains locked until the operating mode is changed. 

  Pressing the buttons of RC-panel and RC-button (“

Exit

”) is ignored. 

  When a card is presented, an access violation event is registered. 

 “

Security”

1

 operating mode. 

  OD remains locked until the operating mode is changed. 

  Pressing the buttons of RC-panel is ignored. 

                                                

1

 Operating mode is available only for “

Controller for the locks

” configuration and for connected 

CL-201

 lock 

controllers. 

Summary of Contents for CT/L-14

Page 1: ...Controller CT L 14 ASSEMBLY AND OPERATION MANUAL...

Page 2: ...CT L 14 Controller Assembly Operation Manual...

Page 3: ...13 8 2 Installation order 14 8 2 1 Controller installation 14 8 2 2 Door control configuration 16 8 2 3 Turnstile and electromechanical gates configuration 18 8 2 4 Vehicle checkpoint configuration 2...

Page 4: ...thernet Appendix 4 p 2 and in browser address bar add the port number 49000 to controller IP address login password for initial entering admin admin After this Web server and system server are to be i...

Page 5: ...ces RS 485 Wiegand1 Number of reading devices via RS 485 interface up to 8 via Wiegand2 interface up to 8 Number of users min 50 000 Event memory capacity up to 150 000 Number of access cards for each...

Page 6: ...and on the item board IP address specified in the certificate and on the item board Subnet mask 255 0 0 0 gateway IP address 0 0 0 0 Following ways to set up IP address gateway and subnet mask are pro...

Page 7: ...board process execution module The XS1 XS2 terminal blocks of the upper board are connected to the XP1 XP2 connectors of the lower board The controller boards are shown in Fig 1 The terminal blocks ap...

Page 8: ...input IN 5 GND Common IN6 In 6 Additional input IN 6 XT2 RC1 connector FA FA Input for emergency unlocking passage opening Fire alarm GND Common DUA DUA 1 Control input of the OD1 from the RC button o...

Page 9: ...r upper board Following ways of IP address setting are possible see Table 2 1 User mode Jumper is removed If the user does not change the IP address gateway subnet mask the controller operates with de...

Page 10: ...t of a turnstile 2 o intrusion detectors of a vehicle checkpoint 2 o optional equipment IN 3 IN4 o door sensor 4 reed switch o PASS output of a turnstile 2 o optional equipment IN 4 IN5 IN6 o optional...

Page 11: ...N 10 DUSt button Stop on the RC panel 2 WRC 2 or optional equipment IN 11 DUB button B on the RC panel 2 WRC 2 or optional equipment IN 12 Activation and signals characteristics of the control element...

Page 12: ...notifications to central surveillance panel connection of other optional equipment Output signals characteristics Maximum commutation voltage of direct current max 30 V Maximum commutated current max...

Page 13: ...03 interface converter up to four readers with the Wiegand interface can be connected to the controller and when using four AC 02 1 converters up to 8 readers can be connected The connection layout a...

Page 14: ...Sect 7 1 Installation should be done in accordance with local building requirements 8 1 Cable lengths Cables for installation are shown in Table 3 Table 3 Cables used for installation N Equipment Cab...

Page 15: ...ning on the controller s board is presented in Fig 1 Installation of connected devices turnstiles locks power supply etc is performed according to the instructions given in technical documents of corr...

Page 16: ...n accordance with the Table 2 if necessary 6 Connect Ethernet cable to X2 connector of the controller upper board 7 Connect power source cable to XT4 terminal block of the controller lower board in ac...

Page 17: ...mechanical electromagnetic locks Sect 8 2 2 turnstile Sect 8 2 3 vehicle checkpoint Sect 8 2 4 RC panel WRC Sect 8 2 5 emergency unlocking devices Fire Alarm Sect 8 2 6 other optional equipment Sect 8...

Page 18: ...of the lock the latch to XT6 or XT9 terminal blocks on the lower board of the controller is performed in accordance with layout Fig 3 5 3 If connection of an Exit lock RC button is required connect it...

Page 19: ...Operation Manual 18 8 2 3 Turnstile and electromechanical gates configuration Figure 6 Connection layouts of Turnstile control configuration...

Page 20: ...iance with the layout Fig 6 3 Connect the turnstile the control unit of the turnstile to XT1 XT8 XT9 terminal blocks of the controller lower board in compliance with the layout Fig 6 4 Connect the swi...

Page 21: ...hicle checkpoint OD are given in Fig 8 Notes Output normalization parameter of OD should be set into After closing mode If operation is performed via one relay Automatic closing function should be tur...

Page 22: ...CT L 14 Controller 21 Figure 8 Connection layouts of boom barriers to the controller of vehicle checkpoint Figure 9 Connection layout of intrusion detectors...

Page 23: ...assage opening of all ODs connected to the controller board and the controllers of the second level except ODs which are in Security operating mode the possibility of emergency unlocking is to be conf...

Page 24: ...ional equipment with inductive load Rn to the outputs it is necessary to use spark protection diode VD1 in Fig 12 For example Schottky diode for operating current of min 1A 1N5819 Figure 11 Connection...

Page 25: ...n Turn on the power source the LED indication is to light up on the controller housing It means that the controller is switched on 2 Connect to the controller Web interface via Ethernet network Append...

Page 26: ...ler Web interface using computer via Ethernet Appendix 4 p 2 and in browser address bar add the port number 49000 to controller IP address login password for initial entering admin admin After this We...

Page 27: ...ly transferred to the database on security system server Availability of verification function depends on installed extensions of network software 11 1 ACS operating modes The change of operating mode...

Page 28: ...of the Fire Alarm input Any card 1 3 0 21 off off off No Open on off off off Control off on off off Security off 1 Hz 1 Hz off Closed off off on off Card is not authorized for access Open on off off 0...

Page 29: ...Network settings in the computer are missing set IP address and subnet mask of the computer The controller should be connected either directly to network connector of network card of the computer or t...

Page 30: ...aintenance and monitoring of the technical condition of means of the security fire alarm system Respecting of periodicity technological order and methods of execution of maintenance work are required...

Page 31: ...troller by simulating the actuation of detectors in accordance with the resources configuration Indication on the controller corresponding to events is on Formation of signals at the outputs according...

Page 32: ...CT L 14 Controller 31 APPENDICES Appendix 1 Instruction on connection of the card capture reader Figure 15 IC 05 card capture reader connection layout...

Page 33: ...nfiguring the controller and the IC05 card capture reader is described in the Administrator s Guide of these systems and also in the IC05 Operation Manual An example of connection of the PERCo card ca...

Page 34: ...nd of all the devices powered by it must not exceed 12 W It is also recommended to leave min 10 reserve power Splitter description PoE splitter hereinafter splitter is designed for energizing equipmen...

Page 35: ...roller for lock chamber management Lock chamber is intermediate detached space passage through an OD which excludes a possibility of a pass through without additional verification visual identificatio...

Page 36: ...egard to the lock chamber Reader can be replaced or duplicated by the RC button see below the lock chamber OD settings For comfort of use in the Web interface of the controller the lock chamber is pre...

Page 37: ...r OD settings To operate the lock chamber passageway control sensors are activated PASS A and PASS B of turnstile 1 for direction of the passages 1 and 2 through OD1 PASS A and PASS B of turnstile 2 f...

Page 38: ...3 5 Reading format of the card identifiers 40 4 CONFIGURATION 41 4 1 Controller configuration template 41 4 2 Configuration of the controller resources settings 42 4 2 1 Operating devices 42 4 2 2 Ph...

Page 39: ...2 3 Make sure that the computer and the controller are on the same subnet Ethernet It may become necessary to change network settings of the computer browser settings and to check operation of the net...

Page 40: ...g devices Physical contacts Readers Internal responses Events filters Access Time access criteria Time zones Holidays Weekly schedule Shift day Flexible weekly Users Operating device control Events St...

Page 41: ...Server in the Web interface menu The page with working area will be opened 2 In the opened window make the necessary changes for the parameters Server address parameter sets the server address Encrypt...

Page 42: ...be reset to the default template parameters The list of recorded access cards identifiers related user information access rights and parameters remain the same To change the configuration of the cont...

Page 43: ...ill be opened 3 In the opened window on the Device management Security General access Access by direction tabs make the necessary changes of the settings for corresponding resources 4 Click the Save b...

Page 44: ...e physical contact is attached to are to be set Inputs and outputs that are not involved in the template the value is Input Output These inputs and outputs are available for the task and changes in th...

Page 45: ...e deleted 4 2 3 Readers In all controller configurations to each direction of every OD one reader or one infrared panel hereafter reader is assigned If necessary it is possible to add into the configu...

Page 46: ...arameter sets line with Trassir server IP address Port parameter sets Trassir server port number Password parameter sets Trassir server authorization password Movement line parameter sets the number o...

Page 47: ...se launch Response time and Response characteristics parameters set corresponding response settings 4 Click the Save button The Internal response window will be closed the changed settings will be pas...

Page 48: ...l command Verification parameter sets the verification confirmation passage counter denial RC panel denial EVD denial Software denial verification timeout no response from passage counter no response...

Page 49: ...t the Cancel button Also it is possible to close the window by clicking Close 6 To delete the time zone from the list click the title bar in the working area the Time zones window will be opened Selec...

Page 50: ...from the list click the title bar in the working area the Holidays window will be opened Click the Delete button The Holidays window will be closed and the selected day will be deleted 5 1 3 Weekly sc...

Page 51: ...lick the Add button to change or delete the Flexible daily schedule parameters click the title bar in the working area The Flexible daily schedule window will be opened 3 In the opened window perform...

Page 52: ...r click the Save button The Flexible weekly schedule window will be closed 5 To exit the Flexible weekly schedule window without saving the changes select the Cancel button Also it is possible to clos...

Page 53: ...ilarly if needed 5 Using the Fingerprints tab assign to the user the fingerprints For this purpose Click the Activate complement button and place the finger on the reader device To delete all the fing...

Page 54: ...Note When arming the direction of the OD associated with the reader is set you select it in the dropdown Direction list When you unlock the OD will be unlocked for the time chosen in the drop down li...

Page 55: ...ut state change Functioning Service 5 Use the Range beginning point and Range end point fields to set the period of the report 6 Click the Apply button to apply the filter click the Cancel button to c...

Page 56: ...from Morpho click the Delete all fingerprints from Morpho button 4 To update the controller software firmware indicate the location of the software file using the Browse button and click the Download...

Page 57: ...PERCo Polytechnicheskaya str 4 block 2 194021 Saint Petersburg Russia Tel 7 812 247 04 64 E mail export perco com support perco com www perco com...

Page 58: ...www perco com...

Reviews: