2018-07
30
VisuNet GMP RM/PC 200 series
Installation and Commissioning
3.3
General Mounting Information
Tools required for assembly
Use the follwing tools for assembly (not included in the scope of supply):
■
Allen key, 3,5 mm, 3 mm, 4 mm
■
4 stainless steel screws (M8) for wall/floor mount
■
Fork wrench for cable glands
Choose the appropriated wrench size to tighten the cable glands:
Clamping Range in the Pedestal - Wrench Size
3.4
Mounting the pedestal
Mounting pedestal on the ground
1. To seal the pedestal against the floor, use the enclosed gasket.
2. Mount the pedestal by using the 4 screws (M8).
Figure 3.5
Pedestal from bottom (photo) and from side (drawing)
1. Pedestal
2. Gasket
3. Ground
Note!
Mounting with 2 persons
The following mounting requires 2 persons.
Note!
For fastening the pedestal, use 4 screws (M8) which suit the soil conditions.
Wrench Size
Cable Diameter
Torque
M16
20
4,5-10 mm
10 Nm
M20
24
7-13 mm
12 Nm
M25
29
9-17 mm
12 Nm
Note!
For fastening the pedestal, use 4 screws (M8) which suit the soil conditions.
1
2
3