Product Description
2
0
1
8
-0
6
23
2.4
Interfaces and Connections
Connections: Inputs/Outputs
The sensors and motors are connected to the ZPA motor control module via cables with round
M8 connectors:
■
Sensors: socket, 4-pin
■
Motors: socket, 5-pin
The signals for zone coupling are connected to the ZPA motor control module via cables with
round M12 connectors.
The exact meaning of the inputs and outputs of the signals for zone coupling depends on the
connection of the ZPA motor control module (see Chapter "Use and Application," Section
"Zone Coupling").
Power Supply
The power supply of the ZPA motor control module is provided using piercing technology with
an AS-Interface flat cable via the PWR contacts of the ZPA motor control module.
Connector Assignment
8
Slave
1-zone operation
9
Reserved
-
Table 2.7
Switch setting
Operation Mode
1-/2-zone operation
Connection
Connector
Connector type/assignment
PWR
Power supply:
black AS-Interface flat cable
(2 x 1.5 mm
2
)
Two pins for piercing technology
-: Negative power supply pole
+: Positive power supply pole
IN1, IN2: sensor
Input:
LF004-GS1-A in accordance with
IEC/EN 61076-2-104
M8, 4-pin, socket, cap nut, coding A
Matching female connector:
LM004-Gx1-A
or similar
1: IN+ sensor supply
2: Not used
3: IN- sensor supply GND
4: IN sensor signal
MOT1, MOT2: motor
Motor:
NF005-SS1-B in accordance with
IEC/EN 61076-2-104
M8, 5-pin, socket, snap-locking, coding B
Matching female connector:
NM005-Sx1-B
or similar
1: MOT+ motor supply
2: DIR direction of rotation
3: MOT- motor supply GND
4: ERROR input for motor fault
5: SPEED speed signal (default value)
BLACK
PWR
+
-
3
1
4
2
3
1
4
2
5