![Pepperl+Fuchs VAZ-2E2A-G20-ZPA1 Manual Download Page 20](http://html1.mh-extra.com/html/pepperl-fuchs/vaz-2e2a-g20-zpa1/vaz-2e2a-g20-zpa1_manual_1527690020.webp)
2
0
1
8
-0
6
20
Product Description
Status LEDs for zone coupling: Conveyor direction from right to left
X2 IN
Yellow
Input from interface 2: Release signal from downstream zone
■
On = Release signal from downstream zone has been set (high
level)
■
Off = Release signal from downstream zone has not been set (low
level)
X2 OUT
Yellow
Output from interface 2: Status of zone sensor at IN2
■
On = Zone sensor has detected conveyed product (high level)
■
Off = Zone sensor has not detected any conveyed product (low
level)
Table 2.4
LED
Color
Description
X1 IN
Yellow
Input from interface 1: Release signal from downstream zone
■
On = Release signal from downstream zone has been set (high
level)
■
Off = Release signal from downstream zone has not been set (low
level)
X1 OUT
Yellow
Output from interface 1: Status of zone sensor at IN1
■
On = Zone sensor has detected conveyed product (high level)
■
Off = Zone sensor has not detected any conveyed product (low
level)
X2 IN
Yellow
Input from interface 2: Status of zone sensor of upstream zone
■
On = Zone sensor has detected conveyed product (high level)
■
Off = Zone sensor has not detected any conveyed product (low
level)
X2 OUT
Yellow
Output from interface 2: Release signal for upstream zone
■
On = Release signal for upstream zone has been set (high level)
■
Off = Release signal for upstream zone has not been set (low
level)
Table 2.5
LED
Color
Description