Basic operating modes
This control interface unit can be configured to operate either as a fixed code control
interface unit or as a read/write control interface unit. The operating mode is selected
by means of DIP switches S4, S5 and S6, located on the top of the unit.
When configured in fixed-code mode, this interface unit is software compatible with
the IRI-KHA6-4HRX and IRI-KHD2-4HRX control interface unit units.
By some kind of switches, the description of the switch-setting "open" corresponds
with "OFF" or "0". The switch-setting "close" corresponds with "ON" or "1".
Basic operation mode
S4
S5
S6
Fixed Code
open
open
open
Read/write
open
close
close
3964R with RK512 Interpreter
open
close
open
3964R without RK512 Interpreter
close
open
open
Switch settings which have not been defined should not be used.