Fuchs Group • Tel.: Germany (06 21) 7 76-0 • USA (330) 4 25 35 55 • Singapore 7 79 90 91 • Internet http://www.pepperl-fuchs.com
D
a
te
of
i
s
s
u
e
2
7
.0
8
.2
001
46
8.2.6
Additional read/write commands for IDC- ... -1K and IMC-40- ... data carriers
Read/write commands
Bild 8.22:
Read/write commands
Structure of a read page command
Bild 8.23:
Structure of a read page command
Example:
A single read attempt at head 4. Read page 2: 6C 04 00 02
Structure of the response message after data has been read
Bild 8.24:
Structure of the response message after data has been read
Example:
The above read page command was erroneous due to a defective
read head: 6C 80 06
Structure of the response message after data has been written
Bild 8.25:
Structure of the response message after data has been written
Example:
Response to the above command after a write operation at head 4:
4D 0F 00
Command
Hex identifier
Auto Read Page
4Ch
Single Read Page
6Ch
Byte 1
Byte 2
Byte 3
Byte 4
Command
Head-no.
Low byte
page
High byte
page
Byte 1
High
Byte 2
Low
Byte 2
Byte 3
Byte 4...
Byte 36
Command
0
Head status
Head-no.
Read Data
Byte 1
High nibble
Byte 2
Low nibble
Byte 2
Byte 3
Command
0
Status/Head