IDENT-I • IVI-KHA6-4HRX, IVI-KHD2-4HRX
Operating control interface units using the 3964R protocol
Subject to reasonable modifications due to technical advances.
Copyright Fuchs, Printed in Germany
Fuchs Group • Tel.: Germany (06 21) 7 76-0 • USA (330) 4 25 35 55 • Singapore 7 79 90 91 • Internet http://www.pepperl-fuchs.com
D
a
te
of
i
s
s
u
e
2
7
.0
8
.2
001
42
8.2.3
Fixed code read commands
Bild 8.11:
Fixed code read commands
Read commands for the basic fixed code operating mode
with read head number
When a read head is specified in a command, it is interrogated once only. The result
(code or error message) will then be transmitted in a SEND message. After successful
transmission, the control interface unit waits for another command.
Bild 8.12:
Structure of response message after a code has been read
Example:
A code was read at read head 4
Read-command without read head number
All connected heads are interrogated once. The codes which are read are transmitted
in packed form in a message. The data structure is as for commands R1 … R4.
Example:
A code was read at read head 2 and 4.
Response: 20 0A 1A 66 0C 8F 4A 65 11 78
Command
Hex identifier
Read Fixed code
20h
Buffered Read Fixed code
21h
Byte 1
High
Byte 2
Low
Byte 2
High
Byte 3
Low
Byte 3
Byte 4 ...
Byte 6
20h
0
Head
Status
Head-no.
Code
Code
} } } } } }