IDENT-I • IVI-KHA6-4HRX, IVI-KHD2-4HRX
Technical data
Subject to reasonable modifications due to technical advances.
Copyright Fuchs, Printed in Germany
Fuchs Group • Tel.: Germany (06 21) 7 76-0 • USA (330) 4 25 35 55 • Singapore 7 79 90 91 • Internet http://www.pepperl-fuchs.com
D
a
te
of
i
s
s
u
e
2
7
.0
8
.2
001
34
7.3
Technical data
Order number
IVI-KHD2-4HRX
IVI-KHA6-4HRX
Power supply
Operation voltage
18 V DC ... 32 V DC
Residual ripple
£
10 %
SS
90 V AC ... 253 V AC
50 ... 60 Hz
Power consumption
max. 5 W
max. 5 VA
Interface
Interface options
(selected via S7 and S8)
RS 232 or RS 422 or RS 485
TTY 20 mA (current loop) passive
Transmission rate
300 ... 19 200 Bit/s
Number of read/write
heads
max. 4
Read/write head power sup-
ply
120 mA/17,5 V DC ± 5 %
Ambient conditions
Operating temperature
-25 °C to +70 °C (248 to 343 Kelvin)
Storage temperature
-25 °C to +85 °C (248 to 358 Kelvin)
Humidity
max. 75 % relative of air humanidity
Schutzart nach EN 60529
IP 20
Interface immunity as in:
EN 50081-2 (ermitted interference)
EN 50082-2 (noise immunity)
Mechanical data
Construction type
60 mm terminal housing
Mounting
Snap-mounted on standard rail to DIN 46277 or
screwed fixing to DIN 43602
Vibration resistance when
installed as specified
To DIN IEC 721 Part 3-5 Class 5M2
Housing method
Makrolon 6485
Plammability class
UL94
Connections
self opening terminals,
max. core cross-section 2x2,5 mm
2
Built-in 9-pin Sub-D-connector