![Pepperl+Fuchs IDENT-M System V MVI-F57-2HB12 Manual Download Page 60](http://html1.mh-extra.com/html/pepperl-fuchs/ident-m-system-v-mvi-f57-2hb12/ident-m-system-v-mvi-f57-2hb12_manual_1527667060.webp)
IDENT-M System V • TCP/IP connection
Description of commands
Zumutbare Änderungen aufgrund technischer Verbesserungen vorbehalten.
Copyright Fuchs, Printed in Germany
Fuchs GmbH • 68301 Mannheim • Telefon (06 21) 7 76-11 11 • Telefax (06 21) 7 76-27-11 11 • Internet http://www.pepperl-fuchs.com
D
a
te
of
is
su
e0
6.
09
.0
1
58
10.30 <BD> Send MVI command directly
This command can be used to send a control command directly to Ident-M System V.
The command code to be transferred, any command from the Microwave Identifica-
tion System manual, should be entered into the TCP output data beginning with byte
9, using the correct syntax.
This sequence is then forwarded from the connecting circuit directly to Ident-M Sys-
tem V. The response of Ident-M System V is then sent back to the TCP input data
beginning with byte 5.
Only commands with an immediate return response of Ident-M System
V are used, since the connecting circuit does not respond to delayed
response messages.
Command:
Designation
Bit number
7
6
5
4
3
2
1
0
Byte 0
X4
X3
X2
X1
K3
K2
K1
-
Byte 1
‚B‘ (0x42)
Byte 2
‚D‘ (0x44)
Byte 3
NC
Byte 4
NC
Byte 5
NC
Byte 6
NC
Byte 7
NC
Byte 8
NC
Byte 9
Command text
- „ -
- „ -
Byte n
- „ -