IDENT-M System V • TCP/IP connection
Commissioning
Zumutbare Änderungen aufgrund technischer Verbesserungen vorbehalten.
Copyright Fuchs, Printed in Germany
Fuchs GmbH • 68301 Mannheim • Telefon (06 21) 7 76-11 11 • Telefax (06 21) 7 76-27-11 11 • Internet http://www.pepperl-fuchs.com
D
a
te
of
is
su
e0
6.
09
.0
1
9
5.2.4
Connection of the read/write heads
For the connection assignment of the write-read heads (antennas) to the MVI-D2-
2HRX Control Interface unit, please refer to the "Ident-M System V manual (Order No.
36916)" of Fuchs. This is located on the accompanying CD-ROM or may be
purchased through the Fuchs homepage. (http://www.pepperl-fuchs.com).
This manual also contains assembly information for the read/write heads regarding
shielding concepts and problems associated with EMC.
5.2.5
Connecting the sensors to the IPC
The industrial PC that is used has 12 digital inputs of which 2,
inputs 0 and 1, are used. Sensor 1 should be connected on input 0 with connector
ST7; sensor 2 should be connected on input 1 with connector ST9.
For the wiring of these inputs, please refer to the wiring diagram (See “Appendix A:
Wiring diagram” on page61.).
5.3
Configuration
5.3.1
Configuration files required
There are 2 configuration files on the IPC.
• The file ip.cfg contains the information required for the network configuration. This
file is changed every time the settings are saved through the display.
• The file startup.bat is executed automatically if the "RUN/STOP" switch of the IPC
is in the "RUN" position.
This file should not be changed.
5.3.2
Configuration of RS232 interfaces
The display communicates via the serial RS232 "COM" interface, while the Control
Interface unit communicates via the "EXT" interface. The following parameters are set
for the interfaces:
The MVI-D2-2HRX Control Interface unit has 4 rotary encoding and DIP switches for
setting transfer parameters.
The "RUN/STOP" switch is only included for development purposes. It
is in the "RUN" position when it is delivered and should not be changed.
If the switch is moved to the STOP position, the application program of
the IPC will run the next time the system starts up, which may result in
failure of the system.
Table 5.1: Settings of the RS232 interfaces
COM (display) interface
EXT (MVI-D2-2HRX) interface
9600 Bd transfer rate
19200 Bd transfer rate
8 data bits
8 data bits
No parity bit (no parity)
No parity bit (no parity)
1 stop bit
1 stop bit