IDENT-M System V • TCP/IP connection
Description of commands
Zumutbare Änderungen aufgrund technischer Verbesserungen vorbehalten.
Copyright Fuchs, Printed in Germany
Fuchs GmbH • 68301 Mannheim • Telefon (06 21) 7 76-11 11 • Telefax (06 21) 7 76-27-11 11 • Internet http://www.pepperl-fuchs.com
D
a
te
of
is
su
e0
6.
09
.0
1
28
10.3
<01> Read ID code, single read Fixcode
Read ID code from data carrier. If no data carrier is present, the appropriate error
message will be sent back.
The structure of the response is as follows if Status == NULL (no error message):
If a status message is present, the Control Interface unit responds with an error mes-
sage that is described in Section 10.2 on page 27 .
Command:
Designation
Bit number
7
6
5
4
3
2
1
0
Byte 0
X4
X3
X2
X1
K3
K2
K1
-
Byte 1
‚0‘ (0x30)
Byte 2
‚1‘ (0x31)
Byte 3
NC
Byte 4
NC
Byte 5
NC
Byte 6
NC
Response for transfer with no errors
Designation
Bit number
7
6
5
4
3
2
1
0
Byte 0
X4
X3
X2
X1
K3
K2
K1
-
Byte 1
‚0‘ (0x30)
Byte 2
‚1‘ (0x31)
Byte 3
Status
Byte 4
I1
T1
S2
S1
EC4
EC3
EC2
EC1
Byte 5
ID code address 8040h
Byte 6
ID code address 8041h
- „ -
ID code address 8042h
- „ -
ID code address 8043h