IDENT-M System V • TCP/IP connection
Description of commands
Zumutbare Änderungen aufgrund technischer Verbesserungen vorbehalten.
Copyright Fuchs, Printed in Germany
Fuchs GmbH • 68301 Mannheim • Telefon (06 21) 7 76-11 11 • Telefax (06 21) 7 76-27-11 11 • Internet http://www.pepperl-fuchs.com
D
a
te
of
is
su
e0
6.
09
.0
1
54
10.27 <MS> Read status
This command can be used to read a status at any time.
If a status message is present, the Control Interface unit responds with an error mes-
sage that is described in Section 10.2 on page 27 .
Command:
Designation
Bit number
7
6
5
4
3
2
1
0
Byte 0
X4
X3
X2
X1
K3
K2
K1
-
Byte 1
‚M‘ (0x4D)
Byte 2
‚S‘ (0x53)
Byte 3
NC
Byte 4
NC
Byte 5
NC
Byte 6
NC
Response for processing with no errors
Designation
Bit number
7
6
5
4
3
2
1
0
Byte 0
X4
X3
X2
X1
K3
K2
K1
-
Byte 1
‚M‘ (0x4D)
Byte 2
‚S‘ (0x53)
Byte 3
Status
Byte 4
I1
T1
S2
S1
EC4
EC3
EC2
EC1
Byte n
- „ -