![Pepperl+Fuchs IDENT-M System V MVI-F57-2HB12 Manual Download Page 31](http://html1.mh-extra.com/html/pepperl-fuchs/ident-m-system-v-mvi-f57-2hb12/ident-m-system-v-mvi-f57-2hb12_manual_1527667031.webp)
IDENT-M System V • TCP/IP connection
Description of commands
Zumutbare Änderungen aufgrund technischer Verbesserungen vorbehalten.
Copyright Fuchs, Printed in Germany
Fuchs GmbH • 68301 Mannheim • Telefon (06 21) 7 76-11 11 • Telefax (06 21) 7 76-27-11 11 • Internet http://www.pepperl-fuchs.com
D
a
te
of
is
su
e0
6.
09
.0
1
29
10.4
<43> Write ID code, single write Fixcode
Write ID code in data carrier. If no data carrier is present, the appropriate error mes-
sage will be sent back.
If a status message is present, the Control Interface unit responds with an error mes-
sage that is described in Section 10.2 on page 27 .
Command:
Designation
Bit number
7
6
5
4
3
2
1
0
Byte 0
X4
X3
X2
X1
K3
K2
K1
-
Byte 1
‚4‘ (0x34)
Byte 2
‚3‘ (0x33)
Byte 3
NC
Byte 4
NC
Byte 5
NC
Byte 6
NC
Byte 7
ID code address 8040h
Byte 8
ID code address 8041h
Byte 9
ID code address 8042h
Byte 10
ID code address 8043h
Response for transfer with no errors
Designation
Bit number
7
6
5
4
3
2
1
0
Byte 0
X4
X3
X2
X1
K3
K2
K1
-
Byte 1
‚4‘ (0x34)
Byte 2
‚3‘ (0x33)
Byte 3
Status
Byte 4
I1
T1
S2
S1
EC4
EC3
EC2
EC1