VB24
35
4
CBX ELECTRICAL CONNECTIONS
All VB24 models are equipped with a cable terminated by a 25-pin male D-sub connector for
connection to the power supply and input/output signals.
We recommend making system connections through one of the CBX connection boxes since
they offer the advantages of easy connection, easy device replacement and filtered reference
signals.
NOTE
If you require direct wiring to the scanner the details of the connector pins
and relative connections are indicated in Chaper 5
The table below gives the pinout of the CBX100/500 terminal block connectors. Use this
pinout when the VB24 reader is connected by means of the CBX100/500:
CBX100/500 Terminal Block Connectors
Input Power
Vdc
Power Supply Input V
GND
Power Supply Input Voltage -
Earth
Protection Earth Ground
Inputs
+V
Power Source – External Trigger
I1A
External Trigger A (polarity insensitive)
I1B
External Trigger B (polarity insensitive)
-V
Power Reference – External Trigger
+V
Power Source – Inputs
I2A
Input 2 A (polarity insensitive)
I2B
Input 2 B (polarity insensitive)
-V
Power Reference – Inputs
Outputs
+V
Power Source - Outputs
-V
Power Reference - Outputs
O1+
Output 1 +
O1-
Output 1 -
O2+
Output 2 +
O2-
Output 2 -
Auxiliary Interface
TX
Auxiliary Interface TX
RX
Auxiliary Interface RX
SGND
Auxiliary Interface Reference
ID-NET™
REF
Network Reference
ID+
ID-NET™ n
Summary of Contents for FUQ-B8
Page 1: ...VB24 BARCODE SCANNER FABRIKAUTOMATION MANUAL ...
Page 22: ...VB24 12 b Operating mode selection and definition c Digital Outputs configuration ...
Page 55: ...VB24 45 Figure 29 ID NET Network Connections with Common Power Branch Network ...
Page 56: ...VB24 46 Figure 30 ID NET Network Connections with Common Power Star Network ...
Page 73: ...VB24 63 Figure 53 ID NET Network Connections with Common Power Branch Network ...
Page 74: ...VB24 64 Figure 54 ID NET Network Connections with Common Power Star Network ...
Page 112: ...VB24 102 T Technical Features 108 Troubleshooting 105 Typical Layouts 77 ...