VB24
65
5.3.3
ID-NET™ Network Termination
The network must be properly terminated by a 120 Ohm resistor at the first and last scanner of
the network.
5.4
AUXILIARY RS232 INTERFACE
The auxiliary serial interface is used exclusively for RS232 point-to-point connections.
The parameters relative to the aux interface (baud rate, data bits, etc.) as well as particular
communication modes such as LOCAL ECHO can be defined using the Genius™ utility
program or Genius™ based Host Mode Programming.
The following pins of the 25-pin connector are used to connect the RS232 auxiliary interface:
Pin
Name
Function
20
RX
Receive Data
21
TX
Transmit Data
7
GND
Ground
7
GND
GND
TXD
RX
20
RXD
TX
21
USER INTERFACE
VB24
1
Chassis
Figure 55 - RS232 Auxiliary Interface Connections