VB24
73
In this layout a single scanner functions as a Slave node on a Fieldbus network. The data is
transmitted to the Host through an accessory Fieldbus interface board installed inside the
CBX500 connection box.
Scanner configuration can be accomplished through the Auxiliary interface using the Genius™
configuration program or Genius™ based Host Mode programming.
In Local Echo communication mode, data is transmitted on the RS232 auxiliary interface
independently from the Fieldbus interface selection.
When On-Line Operating mode is used, the scanner is activated by an External Trigger
(photoelectric sensor) when the object enters its reading zone.
Figure 68 – Fieldbus Interface Point-to-Point Layout
VB24
1
2
3
Fieldbus Interface (Profibus, Ethernet, DeviceNet, etc.)
Auxiliary Serial Interface (Local Echo) (RS232)
External Trigger (for On-Line Mode)
Host
Power
CBX500
Summary of Contents for FUQ-B8
Page 1: ...VB24 BARCODE SCANNER FABRIKAUTOMATION MANUAL ...
Page 22: ...VB24 12 b Operating mode selection and definition c Digital Outputs configuration ...
Page 55: ...VB24 45 Figure 29 ID NET Network Connections with Common Power Branch Network ...
Page 56: ...VB24 46 Figure 30 ID NET Network Connections with Common Power Star Network ...
Page 73: ...VB24 63 Figure 53 ID NET Network Connections with Common Power Branch Network ...
Page 74: ...VB24 64 Figure 54 ID NET Network Connections with Common Power Star Network ...
Page 112: ...VB24 102 T Technical Features 108 Troubleshooting 105 Typical Layouts 77 ...