background image

 
 
 

 
 
 

SD Switch Rugged, 16-Port Specifications 

LAN Interface 

8x 802.3at (PoE+) GE Ports,  
8x GE Ports  
2x SFP Ports 

VLAN Groups 

Yes 

Fiber Module: 

2x 1 Gbps 

Power Input 

AC Input 100V-240V  
DC Output 54V# 

Power Consumption 

20W System,  
90W PoE+ Power Budget 
(supports up to 240W# ) 

Dimensions 
(L x W x H) 

7.5 x 9.0 x 1.5 inches 
190 x 226 x 35 mm 

Weight 

4.4 pounds 
2 kg 

Operating Temperature 

-40° – 149°F 
-40° – 65°C  

Humidity 

15% - 95% (non-condensing) 

Warranty 

1-Year limited Warranty 

 
# The bundled PSU provides 90W of PoE power budget. If you require 240W of power budget, please add 180W PSU (ACW-623) to 
your device 

 

 

 

 
Copyright & Trademarks 

Specifications are subject to change without notice. Copyright © 2020 Pepwave Ltd. All Rights Reserved. Pepwave and the Pepwave logo are 
trademarks of Pepwave Ltd. Other brands or products mentioned may be trademarks or registered trademarks of their respective owners.

 

Summary of Contents for PEPWAVE SD Switch 48-Port

Page 1: ...ch Firmware 1 2 2 May 2020 Copyright Trademarks Specifications are subject to change without notice Copyright 2020 Pepwave Ltd All Rights Reserved Pepwave and the Pepwave logo are trademarks of Pepwav...

Page 2: ...ANs 23 Define a new VLAN 25 Default VLAN Settings 26 InControl Device Details 27 Port details 29 Port Details and Configuration 30 Port List 31 LACP Link Aggregation 32 InControl Reports 33 InControl...

Page 3: ...ne menu options System InControl 59 Standalone menu options System Configuration 60 Standalone menu options System Reboot 61 Standalone menu options System Tools Ping 62 Standalone menu options System...

Page 4: ...ny web browser Simplify management and cut down maintenance time by unifying your VLAN management across all your Peplink devices routers and switches Peplink SD switches are available with 8 16 24 or...

Page 5: ...s Specifications are subject to change without notice Copyright 2020 Pepwave Ltd All Rights Reserved Pepwave and the Pepwave logo are trademarks of Pepwave Ltd Other brands or products mentioned may b...

Page 6: ...160 x 43 mm Weight 2 2 pounds 1 kg Operating Temperature 40 149 F 40 65 C Humidity 15 95 non condensing Warranty 1 Year limited Warranty The bundled PSU provides 90W of PoE power budget If you requir...

Page 7: ...ations are subject to change without notice Copyright 2020 Pepwave Ltd All Rights Reserved Pepwave and the Pepwave logo are trademarks of Pepwave Ltd Other brands or products mentioned may be trademar...

Page 8: ...4 pounds 2 kg Operating Temperature 40 149 F 40 65 C Humidity 15 95 non condensing Warranty 1 Year limited Warranty The bundled PSU provides 90W of PoE power budget If you require 240W of power budget...

Page 9: ...ations are subject to change without notice Copyright 2020 Pepwave Ltd All Rights Reserved Pepwave and the Pepwave logo are trademarks of Pepwave Ltd Other brands or products mentioned may be trademar...

Page 10: ...t 11 3 pounds 5 14 kg Operating Temperature 40 149 F 40 65 C Humidity 15 95 non condensing Warranty 1 Year limited Warranty The bundled PSU provides 120W of PoE power budget If you require 250W of pow...

Page 11: ...ns are subject to change without notice Copyright 2020 Pepwave Ltd All Rights Reserved Pepwave and the Pepwave logo are trademarks of Pepwave Ltd Other brands or products mentioned may be trademarks o...

Page 12: ...er Budget Dimensions 19 1 x 15 7 x 1 7 inches 485 x 400 x 45 mm Weight 13 7 pounds 6 2 kg Operating Temperature 32 104 F 0 40 C Humidity 15 95 non condensing Warranty 1 Year limited Warranty Copyright...

Page 13: ...ns are subject to change without notice Copyright 2020 Pepwave Ltd All Rights Reserved Pepwave and the Pepwave logo are trademarks of Pepwave Ltd Other brands or products mentioned may be trademarks o...

Page 14: ...Dimensions 19 1 x 15 7 x 1 7 inches 485 x 400 x 45 mm L x W x H Weight 15 4 pounds 7 0 kg Operating Temperature 32 104 F 0 40 C Humidity 15 95 non condensing Warranty 1 Year limited Warranty Copyright...

Page 15: ...ut of Band management through USB modem and Console LAN Bypass available on 16 port switch only is a fault tolerance feature that protects your essential business communications in the event of a fail...

Page 16: ...ted SFP for 24 48 ports model SFP for 8 and 16 ports model Connect to the Management Port The management port is designed for Out of Band management The SD Switch can be managed via this port only by...

Page 17: ...Console Port Access the SD Switch via this port with CLI to get the status and info of the switch This is currently under development Copyright Trademarks Specifications are subject to change without...

Page 18: ...our InControl documentation Add the Switch to InControl 1 Logon to InControl and create a separate group for your Peplink switch Add the switch serial number and follow the onscreen instructions 2 Co...

Page 19: ...eeds to be enabled to allow the Peplink Switch to be configured through InControl This setting is enabled by default The settings can be changed in the local web interface of the Switch In Incontrol b...

Page 20: ...ce Management The InControl Group Settings device details shows tags product name uptime online time clients and firmware for each device This pageview also allows you to configure switch specific opt...

Page 21: ...will only be forwarded to switch ports that are configured with the Allow DHCP Server option i port details Default setting disabled Copyright Trademarks Specifications are subject to change without n...

Page 22: ...lity The priority field specifies the bridge priority for root switch election The switch with the lowest bridge priority is elected as the root switch Default value 32768 Copyright Trademarks Specifi...

Page 23: ...works has several Switch specific settings and behaviors Copyright Trademarks Specifications are subject to change without notice Copyright 2020 Pepwave Ltd All Rights Reserved Pepwave and the Pepwave...

Page 24: ...ult IP Address setting The DHCP server will be enabled with default settings When a Switch is added to a group in InControl a Management Port and Management VLAN are imported from the local Switch to...

Page 25: ...desired parameters and click Save to apply the settings Copyright Trademarks Specifications are subject to change without notice Copyright 2020 Pepwave Ltd All Rights Reserved Pepwave and the Pepwave...

Page 26: ...frames will be assigned to VLAN 1 Any frames on VLAN 1 leaving from those ports will be untagged After review this setting needs to be saved once to confirm Tip 1 If you want untagged frames to be fo...

Page 27: ...N IP Temperature Uptime Connected GE ports Power source Online Connected SFP SFP ports Location First Appeared InControl Detected IP Port List History event log Usage Copyright Trademarks Specificatio...

Page 28: ...e details page Or Cancel to discard changes and return to the Device Settings page Copyright Trademarks Specifications are subject to change without notice Copyright 2020 Pepwave Ltd All Rights Reserv...

Page 29: ...SFP ports fibre Port Icons Glossary port down port up PoE not drawing power port up PoE drawing power port up link to InControl Port up PoE disabled Copyright Trademarks Specifications are subject to...

Page 30: ...able or disable PoE on the port Speed Select ports speeds 10 or 100 Mbps half or full Duplex or 1 Gbps full Duplex Port Type Trunk or Access port VLAN All or CUSTOM select 1 or more existing VLANs Cop...

Page 31: ...oping on the switch is enabled on the switch When DHCP snooping is enabled on the switch this option enables DHCP snooping for the individual ports setting the option as per the default setting on the...

Page 32: ...sing an individual port include higher throughput speed compared to an individual port higher accessibility To configure a Link Aggregation Group LAG click Edit after selecting multiple ports Copyrigh...

Page 33: ...in a graph on the same page InControl Reports Search through the SD Switch event logs filter results by topic time client and details Download the event log in csv format InControl Clients Copyright...

Page 34: ...l group and Device Tools Settings Remote Web Admin Remote Web Admin opens the web admin interface of the SD Switch in a separate tab Settings Firmware Management Copyright Trademarks Specifications ar...

Page 35: ...e allowed to communicate with InControl Alternatively configure this option as Enable Restricted to Status Reporting Only to be able to monitor the switch through InControl but manage it from the loca...

Page 36: ...source status Model Power Consumption Port List When hovering over a port a popup window with port details displays the following information Copyright Trademarks Specifications are subject to change...

Page 37: ...arked with a in the overview VLANs that are managed by InControl are marked with a cogwheel To define a new VLAN select the New LAN option Copyright Trademarks Specifications are subject to change wit...

Page 38: ...er VLAN routing The inter VLAN routing IP address is used for Layer 3 routing on this VLAN This address cannot be the same as the above IP address but needs to be in the same subnet range Copyright Tr...

Page 39: ...AN needs the switch to have a router interface for inter VLAN routing to work Standalone menu options Configure STP Spanning Tree Protocol STP uses Spanning Tree Algorithm to avoid network loops in la...

Page 40: ...ed port Standalone menu options Configure Access Control Ingress ACL Switch ports can be configured to limit access using an Ingress Access Control List ACL The purpose of ingress inbound ACL is to sp...

Page 41: ...ify one or more MAC addresses Action Allow Deny This option allows you to define whether to allow or deny a frame matching this rule Copyright Trademarks Specifications are subject to change without n...

Page 42: ...n Port Settings when this option is saved and applied See Standalone menu options Configure Interfaces Switch Ports Standalone menu options Configure Port Mirroring With port mirroring enabled the swi...

Page 43: ...nooping is on a per LAN basis add new entries to the IGMP snooping table to activate IGMP snooping on a particular LAN Configure an IGMP snooping querier to send membership queries When an IGMP snoopi...

Page 44: ...e to Configure Switch Ports and then click the pen icon for the port you wish to configure Copyright Trademarks Specifications are subject to change without notice Copyright 2020 Pepwave Ltd All Right...

Page 45: ...Trunk or Access Accept Frame Type The Accept Frame Type setting determines whether the frame should be accepted or discarded VLAN Networks select one or more VLANs Copyright Trademarks Specifications...

Page 46: ...ing changes click Save and then click the Apply Changes button on the top right corner of the interface Authentication Method is only visible after configuring Port based 802 1X Authentication Availab...

Page 47: ...ase one link goes down Select multiple ports by clicking on them and selecting the Link Aggregation checkbox to enable link aggregation for the selected ports Batch Configuration Configure multiple po...

Page 48: ...anagement when it has lost all other external network access The connected USB Modem will remain in cold standby mode until the external access connection fails to contact the Peplink InControl server...

Page 49: ...bject to change without notice Copyright 2020 Pepwave Ltd All Rights Reserved Pepwave and the Pepwave logo are trademarks of Pepwave Ltd Other brands or products mentioned may be trademarks or registe...

Page 50: ...ly username User password User password Web Session Timeout A web login session will be logged out automatically when it has been idle longer than Copyright Trademarks Specifications are subject to ch...

Page 51: ...P HTTPS sessions or both are allowed to connect to the web admin interface Web Admin Port Port to connect to the web admin interface default port is 80 for HTTP and 443 for HTTPS Web Admin Access Acce...

Page 52: ...o allow emergency access The Authentication Protocols supported are MS CHAPv2 and PAP Management Port Settings Configure the management port IP address and subnet mask Other Web Admin Access Settings...

Page 53: ...ne menu options System Time This section allows you to select a Time Zone and configure a Time Server Standalone menu options System Schedule Schedules can be created and applied to port PoE settings...

Page 54: ...n Copyright Trademarks Specifications are subject to change without notice Copyright 2020 Pepwave Ltd All Rights Reserved Pepwave and the Pepwave logo are trademarks of Pepwave Ltd Other brands or pro...

Page 55: ...nges text on the top right corner to save your changes Copyright Trademarks Specifications are subject to change without notice Copyright 2020 Pepwave Ltd All Rights Reserved Pepwave and the Pepwave l...

Page 56: ...d Test Notification to send a testing email Standalone menu options System Event Log Remote Syslog allows syslog messages to be sent to a specified remote syslog server You can configure a remote sysl...

Page 57: ...ystem Admin Security SNMP Port This option specifies the port which SNMP will use The default port is 161 SNMPv1 This option allows you to enable SNMP version 1 SNMPv2 This option allows you to enable...

Page 58: ...et mask To define a username for SNMPv3 click Add SNMP User in the SNMPv3 User Name table upon which the following screen is displayed SNMPv3 User Settings User Name This setting specifies a user name...

Page 59: ...s with one unified system With it you can generate reports gather statistics and configure your devices automatically All of this is now possible with InControl When the InControl settings is configur...

Page 60: ...e their usage reports and receive offline notifications Standalone menu options System Configuration Backing up the Peplink SD Switch settings immediately after successful completion of initial setup...

Page 61: ...Reboot Reboot the switch For maximum reliability the Peplink SD Switch Series stores two copies of firmware and each copy can be a different version of firmware You can select the firmware version you...

Page 62: ...ular LAN WAN connection Standalone menu options System Tools Traceroute The traceroute test tool traces the routing path to a particular destination A system administrator can use the traceroute utili...

Page 63: ...tely power on the client device Standalone menu options Status Device This page displays the device s system information System information Switch name This is the name specified in the Switch Name Co...

Page 64: ...current system time Diagnostic report The Download link is for exporting a diagnostic report file required for system investigation Remote Assistance Click Turn on to enable remote assistance Legal T...

Page 65: ...he SD switch STP bridge ID and Root ID Standalone menu options Status Event Log The log section displays a list of events that has taken place on the SD Switch Check Auto Refresh to refresh log entrie...

Page 66: ...eset button Hold for 5 10 seconds for admin password reset Note The LED status light blinks in RED 2 times and release the button green status light starts blinking Hold for approximately 20 seconds f...

Page 67: ...Community Forums https forum peplink com Contact Us Sales http www peplink com contact sales Support http www peplink com contact Certified Peplink Partner http www peplink com partners channel partn...

Reviews: