background image

2

3

WhisperFlo VS 1500 

Owner’s Manual 

WhisperFlo VS 1500

 Owner’s Manual

ECO SELECT

®

The Eco Select

®

 brand identifies our most eco-friendly products

As the global leader in pool and spa equipment, we’ve made a strong commitment to develop 
and offer the most environmentally responsible products available.

When you see the Eco Select

®

 brand on one of our products, you’ll know it is our “greenest” 

and most efficient product in that equipment category.

These products do the best job of saving energy, conserving water, reducing noise, or 
otherwise contributing to a more environmentally responsible equipment system. In every 
case, a product that earns the Eco Select brand is clearly our “greenest” and most efficient 
choice.

TABLE OF CONTENTS

Page

Features and Benefits 

 

 

 

4

Technical Information 

Model 

Data     

5

Hydraulic Performance 

6

Dimensions 6

Installation 

     

Pump 

Positioning     

7

Piping 8

Pool Outlets 

8

Electrical 

    

9

Equipotential Bonding 

9

Operation 

      

Priming 

the 

Pump     

10

Control Panel Overview 

11

Setting Clock 

12

Using 

Default 

Schedule 

    

13

Custom 

Schedules 

    

14

Operation While Pump is Running 

 

 

 

 

16

Quick 

Clean 

    

18

Keypad 

Lockout 

    

19

Factory 

Reset 

    

20

External 

Controls     

21

Troubleshooting 

Maintenance 

      

Routine 

Maintenance 

    

24

Troubleshooting 25

Spare 

Parts 

      

28

Summary of Contents for WHISPERFLO VS 1500

Page 1: ...thistype of equipment you should contact the distributor manufacturer for the correct advice before proceedingwiththeinstallationoroperationofthisproduct Thepumpoperatororownermust be provided with th...

Page 2: ...noise or otherwise contributing to a more environmentally responsible equipment system In every case a product that earns the Eco Select brand is clearly our greenest and most efficient choice TABLE...

Page 3: ...nents and superior hydraulic design deliver effortless performance energy savings and extended pump life A heavy duty construction and a motor rated for continuous operation make the WhisperFlo VS 150...

Page 4: ...or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the pump The WhisperFlo VS 1500 is electrical...

Page 5: ...An RCD with maximum rated residual current of 30mA is required for the power supply to the pump Additionally if a suitable socket outlet is not available a weatherproof socket must be installed by an...

Page 6: ...rime now Priming time will depend on vertical height of suction lift and horizontal length of suction piping but is generally between 30 seconds to 3 minutes under normal installation conditions j The...

Page 7: ...rrows to adjust the screen backlight brightness 7 Press Display to exit the Clock Setup menu The clock is now set During a power outage the drive will retain the clock setting in memory for as long as...

Page 8: ...any of the SPEEDs can be programmed to 0 RPM This will cause the pump to remain stationary paused throughout the duration of that SPEED Speed Priorities Non External Control For schedule duration set...

Page 9: ...g mode ENABLED Unless the Priming settings are changed in the menu be aware that the pump will speed up to the priming speed when the pump is powered on for the first time and the start stop button is...

Page 10: ...ngaged to temporarily run at higher or lower speeds ranging between 300 to 3150 RPM Once the Quick Clean duration has elapsed the pump will automatically return to the programmed schedule The installe...

Page 11: ...gital Control The WhisperFlo VS 1500 provides a low voltage output signal that can be used to trigger its own Digital Inputs This signal will need to be switched via the External Control system to eng...

Page 12: ...ED 4 DIGITAL INPUT BLACK GROUND EXTERNAL LOW VOLTAGE SUPPLY 5 30 V AC DC GROUND Figure 11 Low Voltage Power Supply Wiring Diagram Note If the pump has been stopped via the Start Stop button the pump w...

Page 13: ...an and inspect lid o ring reinstall on trap Clean O ring groove on trap body and replace cover To help keep cover from sticking tighten hand tight only 5 Prime pump refer priming instructions It is es...

Page 14: ...between the HMI and Motor control has been lost Check the jacketed wire on the back side of the keypad inside the drive top cover Ensure that the 5 pin connector is properly plugged into the socket an...

Page 15: ...asing see pump fasteners kit 8 357100 Gasket seal plate 9 073130K Impeller Kit 10 Impeller screw gasket see impeller kit 11 Impeller LH screw see impeller kit 12 072927K Diffuser 13 Diffuser screw see...

Page 16: ...wner s Manual NOTES PURCHASED FROM PURCHASE DATE SERIAL NO MODEL NO IMPORTANT Please attach your sales invoice docket here as proof of purchase should warranty service be required Please do not return...

Page 17: ...ted without our prior written permission All indicated Pentair trademarks and logos are property of Pentair Third party registered and unregistered trademarks logos are the properties of their respect...

Reviews: