background image

28

29

WhisperFlo VS 1500 

Owner’s Manual 

WhisperFlo VS 1500

 Owner’s Manual

SPARE PARTS

18

15

9

10

11

12

17

13

14

8

2

16

3

4

6

7

1

WHFL 1500 VS

ITEM NO.

PART NUMBER

DESCRIPTION

1

355339

MTR SQFL 3/4HPF 1A 1PH 3/4HPF 1A 

1PH

2

070927

PUMP FOOT WHISPERFLO

3

070929

MOTOR SUPPORT PLATE INSERT SELF 

PRIMING PUMP

4

350101

WHISPERFLO TYPE 6A PLATE KIT

5

070429

BOLT, HEX HD CAP, 3/8-16 UNC X 

.875, SS

6

070431

BOLT, HEX HD CAP,  3/8-16 UNC X 

1.75, SS

7

070430

BOLT, HEX HD CAP,  3/8-16 UNC X 

1.25, SS

8

357100

GASKET, SEALPLATE WHISPERFLO

9

073126

1/2 HP WHISPERFLO IMPELLER

10

075713

WASHER, FLAT .50 X 1.250 X .086 

NYLON

11

071652

LOCKSCREW IMPELLER HP PUMP

12

072927

DIFFUSER WHISPERFLO 1/2, 3/4, 1, 

1.5, AND 2 HP

13

071660

SCREW, SKT HD CAP, 4-40 x 1  SS

14

355227

ORING,2-237, 1/8"X3 3/8"ID

15

357243

POT ASSY ALMOND METRIC BSPP W/ 

DIFF

16

072184

WSHR 3/8 ID X 7/8 OD X .05 THK 18-8 

SS

17

071403

HEX NUT NICKEL PLATED BRASS

18

071734_2

OD CUP MOUNTED MATING RING

19

353132S

MOTOR KIT VS 2.0

A

A

B

B

C

C

D

D

E

E

F

F

G

G

H

H

12

12

11

11

10

10

9

9

8

8

7

7

6

6

5

5

4

4

3

3

2

2

1

1

SPARE PARTS

Item No.

Part Number

Description

1

800048

Motor & Drive Assembly

2

357159K

Motor Foot Kit

3

-

Motor Foot Insert (see foot kit)

4

350203K

Seal Plate and Mechanical Seal Kit

6

801291

Pump Fasteners Kit

7

-

Screw pump casing (see pump fasteners kit)

8

357100

Gasket seal plate

9

073130K

Impeller Kit

10

-

Impeller screw gasket (see impeller kit)

11

-

Impeller LH screw (see impeller kit)

12

072927K

Diffuser

13

-

Diffuser screw (see diffuser kit)

14

-

O-ring diffuser (see diffuser kit)

15

070387

Basket

16

-

Washer (see pump fasteners kit)

17

359541

Pump casing assembly

18

071734S

Mechanical seal

  Not Shown

800050

Motor Bearing Kit

800053

Fan Cover

800051

Fan Kit

800049

Keypad Cover

800046

Top cover kit

800047

VS Drive Kit

Supply Cord

If the supply cord is damaged, it must be replaced by the manufacturer (Pentair), its service 
agent or similarly qualified person in order to  avoid a hazard.

Summary of Contents for WHISPERFLO VS 1500

Page 1: ...thistype of equipment you should contact the distributor manufacturer for the correct advice before proceedingwiththeinstallationoroperationofthisproduct Thepumpoperatororownermust be provided with th...

Page 2: ...noise or otherwise contributing to a more environmentally responsible equipment system In every case a product that earns the Eco Select brand is clearly our greenest and most efficient choice TABLE...

Page 3: ...nents and superior hydraulic design deliver effortless performance energy savings and extended pump life A heavy duty construction and a motor rated for continuous operation make the WhisperFlo VS 150...

Page 4: ...or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the pump The WhisperFlo VS 1500 is electrical...

Page 5: ...An RCD with maximum rated residual current of 30mA is required for the power supply to the pump Additionally if a suitable socket outlet is not available a weatherproof socket must be installed by an...

Page 6: ...rime now Priming time will depend on vertical height of suction lift and horizontal length of suction piping but is generally between 30 seconds to 3 minutes under normal installation conditions j The...

Page 7: ...rrows to adjust the screen backlight brightness 7 Press Display to exit the Clock Setup menu The clock is now set During a power outage the drive will retain the clock setting in memory for as long as...

Page 8: ...any of the SPEEDs can be programmed to 0 RPM This will cause the pump to remain stationary paused throughout the duration of that SPEED Speed Priorities Non External Control For schedule duration set...

Page 9: ...g mode ENABLED Unless the Priming settings are changed in the menu be aware that the pump will speed up to the priming speed when the pump is powered on for the first time and the start stop button is...

Page 10: ...ngaged to temporarily run at higher or lower speeds ranging between 300 to 3150 RPM Once the Quick Clean duration has elapsed the pump will automatically return to the programmed schedule The installe...

Page 11: ...gital Control The WhisperFlo VS 1500 provides a low voltage output signal that can be used to trigger its own Digital Inputs This signal will need to be switched via the External Control system to eng...

Page 12: ...ED 4 DIGITAL INPUT BLACK GROUND EXTERNAL LOW VOLTAGE SUPPLY 5 30 V AC DC GROUND Figure 11 Low Voltage Power Supply Wiring Diagram Note If the pump has been stopped via the Start Stop button the pump w...

Page 13: ...an and inspect lid o ring reinstall on trap Clean O ring groove on trap body and replace cover To help keep cover from sticking tighten hand tight only 5 Prime pump refer priming instructions It is es...

Page 14: ...between the HMI and Motor control has been lost Check the jacketed wire on the back side of the keypad inside the drive top cover Ensure that the 5 pin connector is properly plugged into the socket an...

Page 15: ...asing see pump fasteners kit 8 357100 Gasket seal plate 9 073130K Impeller Kit 10 Impeller screw gasket see impeller kit 11 Impeller LH screw see impeller kit 12 072927K Diffuser 13 Diffuser screw see...

Page 16: ...wner s Manual NOTES PURCHASED FROM PURCHASE DATE SERIAL NO MODEL NO IMPORTANT Please attach your sales invoice docket here as proof of purchase should warranty service be required Please do not return...

Page 17: ...ted without our prior written permission All indicated Pentair trademarks and logos are property of Pentair Third party registered and unregistered trademarks logos are the properties of their respect...

Reviews: