background image

6

7

WhisperFlo VS 1500 

Owner’s Manual 

WhisperFlo VS 1500

 Owner’s Manual

0

5

10

15

20

25

0

50

100

150

200

250

300

350

400

450

500

550

600

Head (

m

)

Flow (LPM)

WhisperFlo VS 1500

3150 RPM
2800 RPM
2400 RPM
2000 RPM
1600 RPM
1200 RPM

TECHNICAL INFORMATION

INSTALLATION

WhisperFlo VS 1500 Performance Chart

Hydraulic Performance

 618 

 232 

 301 

 253 

 199 

 142 

 325 

 275 

 132 

WHISPERFLO VS 1500

A

A

B

B

C

C

D

D

E

E

F

F

8

8

7

7

6

6

5

5

4

4

3

3

2

2

1

1

Dimensions

The pump must be installed and serviced by a suitably qualified person in order 
to avoid hazard. Incorrectly installed or tested equipment may fail, causing 
severe injury or property damage.

These instructions are a guide only. Should you the installer or owner of the 
product be unfamiliar with the correct installation or operation of this product 
you should contact a suitably qualified person for advice.

Do not connect system to high pressure or mains water system.

This pump is not intended for use by persons (including children) with reduced 
physical, sensory or mental capabilities, or lack of experience and knowledge, 
unless they have been given supervision or instruction concerning use of the 
appliance by a person responsible for their safety.

Children should be supervised to ensure that they do not play with the pump.

The WhisperFlo VS 1500 is electrically connected. Ensure that it is isolated from 
electrical supply during installation and any subsequent service work.

1. Plan the position of the pump

For best performance, allow pump suction inlet height to be as far below 
water level as possible and allow the use of short, direct suction pipe with 
minimum bends (to reduce friction losses).

 

a.

   Have enough ventilation to keep ambient temperature below the motor’s rated ambient 

temperature whenever the pump is running. If installed in an enclosure/pump house, 
the enclosure must have adequate ventilation (200sq.cm min, inlet & outlet) and air 
circulation. Allow 200mm to keep rear of motor clear.

b.

   Have adequate floor drainage to prevent flooding and be protected from excess 

moisture.

c.

   Be solid, level, rigid and vibration free.

d.

  To reduce vibration and pipe stress, bolt pump to mount. Fixing holes accept 12mm 

fasteners.

e.

  Be within 2m of a power outlet for electrical connection (refer to AS/NZS 3000 for rules 

regarding connection of electrical equipment in pool zones).

f.

  Allow adequate access for servicing pump and piping.

Summary of Contents for WHISPERFLO VS 1500

Page 1: ...thistype of equipment you should contact the distributor manufacturer for the correct advice before proceedingwiththeinstallationoroperationofthisproduct Thepumpoperatororownermust be provided with th...

Page 2: ...noise or otherwise contributing to a more environmentally responsible equipment system In every case a product that earns the Eco Select brand is clearly our greenest and most efficient choice TABLE...

Page 3: ...nents and superior hydraulic design deliver effortless performance energy savings and extended pump life A heavy duty construction and a motor rated for continuous operation make the WhisperFlo VS 150...

Page 4: ...or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the pump The WhisperFlo VS 1500 is electrical...

Page 5: ...An RCD with maximum rated residual current of 30mA is required for the power supply to the pump Additionally if a suitable socket outlet is not available a weatherproof socket must be installed by an...

Page 6: ...rime now Priming time will depend on vertical height of suction lift and horizontal length of suction piping but is generally between 30 seconds to 3 minutes under normal installation conditions j The...

Page 7: ...rrows to adjust the screen backlight brightness 7 Press Display to exit the Clock Setup menu The clock is now set During a power outage the drive will retain the clock setting in memory for as long as...

Page 8: ...any of the SPEEDs can be programmed to 0 RPM This will cause the pump to remain stationary paused throughout the duration of that SPEED Speed Priorities Non External Control For schedule duration set...

Page 9: ...g mode ENABLED Unless the Priming settings are changed in the menu be aware that the pump will speed up to the priming speed when the pump is powered on for the first time and the start stop button is...

Page 10: ...ngaged to temporarily run at higher or lower speeds ranging between 300 to 3150 RPM Once the Quick Clean duration has elapsed the pump will automatically return to the programmed schedule The installe...

Page 11: ...gital Control The WhisperFlo VS 1500 provides a low voltage output signal that can be used to trigger its own Digital Inputs This signal will need to be switched via the External Control system to eng...

Page 12: ...ED 4 DIGITAL INPUT BLACK GROUND EXTERNAL LOW VOLTAGE SUPPLY 5 30 V AC DC GROUND Figure 11 Low Voltage Power Supply Wiring Diagram Note If the pump has been stopped via the Start Stop button the pump w...

Page 13: ...an and inspect lid o ring reinstall on trap Clean O ring groove on trap body and replace cover To help keep cover from sticking tighten hand tight only 5 Prime pump refer priming instructions It is es...

Page 14: ...between the HMI and Motor control has been lost Check the jacketed wire on the back side of the keypad inside the drive top cover Ensure that the 5 pin connector is properly plugged into the socket an...

Page 15: ...asing see pump fasteners kit 8 357100 Gasket seal plate 9 073130K Impeller Kit 10 Impeller screw gasket see impeller kit 11 Impeller LH screw see impeller kit 12 072927K Diffuser 13 Diffuser screw see...

Page 16: ...wner s Manual NOTES PURCHASED FROM PURCHASE DATE SERIAL NO MODEL NO IMPORTANT Please attach your sales invoice docket here as proof of purchase should warranty service be required Please do not return...

Page 17: ...ted without our prior written permission All indicated Pentair trademarks and logos are property of Pentair Third party registered and unregistered trademarks logos are the properties of their respect...