Page 22
Status Query
Important parameters of the heat pump’s current
status can be viewed on the status screen.
1. On the main interface screen, swipe left and tap
to enter into the status menu.
2. Tap the status button
to enter the status
display.
Machine Status:
(ON/OFF) - Displays whether the
heat pump is currently on or off.
Operating Mode: (Heating / Cooling / Auto) - Displays
whether the heat pump is currently in heating, cool-
ing or auto mode.
Comp� Frequency:
(30-95Hz) - Displays the supply
frequency of the inverter compressor.
Inlet Temp:
(5-40
0
C) - Displays the water temperature
at the inlet of the heat pump. This is the water tem-
perature of the pool.
Outlet Temp:
(5-40
0
C) - Displays the water temper-
ature at the outlet of the heat pump. This should be
1-2
0
C warmer than the inlet temp while in heating
mode or 1-2
0
C cooler than the inlet temp while in
cooling mode. If the temperature difference is higher
than 2
0
C, adjust the water flow so there is more water
flowing through the heat pump.
Ambient Temp:
Displays the current ambient tem-
perature of the air around the heat pump. If the
temperature differs greatly from the actual temper-
ature of the day, it could be that the heat pump does
not have adequate clearance to properly circulate it’s
exhaust air.