SMART UV® UV DISINFECTION STERILIZER Installation and User's Guide

  IMPORTANT NOTICE

This guide provides installation and operation instructions for the 
SMART UV

®

 Sterilizer. Consult Pentair with any questions regarding 

this equipment.
Attention Installer: This guide contains important information 
about the installation, operation and safe use of this product. This 
information should be given to the owner and/or operator of this 
equipment after installation or left on or near the UV system.
Attention User: This manual contains important information that will 
help you in operating and maintaining this product. Please retain it for 
future reference.
IMPORTANT SAFETY INSTRUCTIONS! PLEASE READ PRIOR 
TO INSTALLATION AND OPERATION!
Strictly follow the instructions within this manual to ensure the health 
and safety of both, yourself and the UV system. The installation, 
operation and maintenance of the UV system can only be carried out 
after reading and understanding the information contained in this 
manual.
The installation of the UV system must be carried out in accordance 
with local regulations and codes.

READ AND FOLLOW ALL INSTRUCTIONS

  This is the safety alert symbol. When you see this symbol on 

your system or in this manual, look for one of the following signal 
words and be alert to the potential for personal injury.

   Warns about hazards that can cause death, 

serious personal injury, or major property 
damage if ignored.

   Warns about hazards that may cause death, 

serious personal injury, or major property 
damage if ignored.

   Warns about hazards that may or can cause 

minor personal injury or property damage if 
ignored.

NOTE 

 Indicates special instructions not related to 
hazards.

Carefully read and follow all safety instructions in this manual and 
on equipment. Keep safety labels in good condition; replace if 
missing or damaged.

When installing and using this electrical equipment, basic 
safety precautions should always be followed, include the 
following:

  FAILURE TO FOLLOW ALL INSTRUCTIONS AND 

WARNINGS CAN RESULT IN SERIOUS BODILY INJURY OR 
DEATH.
INSTALLERS, OPERATORS AND OWNERS MUST READ THESE 
WARNINGS AND ALL INSTRUCTIONS IN THE OWNER’S 
MANUAL BEFORE USING THIS PRODUCT. THESE WARNINGS 
AND THE OWNER’S MANUAL MUST BE LEFT WITH THE 
OWNER.

  Ultraviolet light is damaging to your eyes and skin! DO 

NOT handle or stare at an operating UV lamp. Note that the UV light 
rays are invisible to the human eye and precautions should be taken 
to prevent UV energy from entering the eyes.

  ULTRAVIOLET RADIATION. Disconnect all power 

from the unit before replacing lamps or servicing the unit.

  The quartz sleeve and or the UV lamp shipped with 

this product may have been broken or damaged during transit. It 
is therefore essential that the unit be carefully inspected before 
connecting to electrical power.

  To prevent possible fire or electrical shock, only use 

replacement lamps specified by the manufacturer.

  DO NOT allow system to exceed 50 PSI (Pounds Per 

Square Inch).

  DO NOT operate this unit above rated flow rate. 

Operating the product in this manner may result in product failure 
and voiding of warranty.

  To avoid possible electrical shock, special care should 

be taken since water is employed in intended applications. For each 
of the following situation, DO NOT attempt repairs yourself. Call 
Pentair customer service department at 877-347-4788 for services or 
discard the appliance.

  If unit falls into the water, DO NOT REACH FOR IT! 

First power down the unit and then retrieve it. If the internal electrical 
components of the unit get wet, keep the unit powered down until 
internal electrical components have dried.

  If the unit shows any sign of water leakage, immediately 

power down the unit.

  Carefully examine the unit after installation. It should 

not be powered on if there is water on any part not intended to be wet.

IMPORTANT SAFETY INSTRUCTIONS

Summary of Contents for SMART UV E120S

Page 1: ...IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS SMART UV UV DISINFECTION STERILIZER INSTALLATION AND USER S GUIDE...

Page 2: ...are not used to indicate an affiliation or endorsement between the owners of these names and brands and Pentair Aquatic Eco Systems Inc Those names and brands may be the trademarks or registered trad...

Page 3: ...uartz Sleeve Assembly and Installation 9 Sterilizer Installation and Operation 10 Typical Installation 10 Mounting the Vessel 10 Mounting the Power Supply 11 Mandatory Leak Test 11 Electrical Connecti...

Page 4: ...missing ordamaged When installing and using this electrical equipment basic safety precautions should always be followed include the following FAILURE TO FOLLOW ALL INSTRUCTIONS AND WARNINGS CAN RESU...

Page 5: ...ay overheat Care should be taken to arrange the cord so that it will not be tripped overor pulled If in doubt consult a qualified electrician Warping of the UV body may occurwhen left in direct sunlig...

Page 6: ...t the highest UV C output conversion among all UV lamps UL listed for indoor and outdoor use fresh and salt water use Long lasting GPH T5 and GPH T6 UV lamps 9 000 hours to 80 efficiency Protective Qu...

Page 7: ...EU18 U EU25 U EU40 EU65P SMART UV HO Sterilizer Models Part Numbers E50S E80S E120S E150S Power Supplies The power supply can either be a cylinder POD or a rectangle style Below are the ballasts that...

Page 8: ...ontact the place of original purchase immediately NOTE Save the corrugated lamp packaging after unpacking the UV lamp Storing the lamp and or quartz sleeve in this packaging while performing maintenan...

Page 9: ...sleeve module use your index finger to ensure that the open end of the quartz sleeve mates smoothly with the inside lip of the clear quartz sleeve module this signifies a good fit See Photo A 5 With...

Page 10: ...important role in the unit s performance and degree of safety We STRONGLY RECOMMEND that you follow these instructions and guidelines precisely Any deviation from these mounting instructions will voi...

Page 11: ...uartz sleeve module has been achieved Failure to achieve a proper quartz sleeve quartz sleeve module seal during SMART UV Disinfection Sterilizer operation will allow water to leak into the inside of...

Page 12: ...er or pulled If in doubt consult a qualified electrician GFCI s are designed to sense an imbalance in electrical current flow within the main electrical leads leakage current When this imbalance maxim...

Page 13: ...UV lamp power cord connection complete and the lamp entirely inside the quartz sleeve carefully screw down the Gray Power Supply Adapter 3 onto the Clear Quartz Sleeve Module 6 hand tighten only 5 Scr...

Page 14: ...al tape on all threaded connections Larger Sized Ponds above 5 000 Gallons Using Surface Skimmer and Pressurized Filter This system is simple yet it achieves critical filtering goals such as good wate...

Page 15: ...water flow meter manufacturer s instructions for proper installation and operation See Diagram 4 NOTE Before gluing piping or reducer bushing into the UV s union or socket remove the quartz sleeve ass...

Page 16: ...sits If using muriatic acid a ratio of four parts water to one part acid should suffice Always introduce acid to the water and never introduce the water to the acid Muriatic acid is corrosive and can...

Page 17: ...n solder to make them firm enough to push back in the new lamp connector NOTE Clean away any residual flux off of the wires before assembling them into the lamp connector 7 Using a new 4 pin lamp conn...

Page 18: ...aker is tripping 1 Immediately disconnect power to the SMART UV Disinfection Sterilizer 2 Turn off the pool pump at the circuit breaker and be sure all flow to the unit has been stopped 3 Refer to pag...

Page 19: ...unions EU18 U 18 WATT 960359 EU25 U 25 WATT 20425 EU40 40 WATT 20440 EU65P 65 WATT 20465 EU80P 80 WATT NA EU130P 130 WATT NA KITS ITEM Quartz Sleeve Module QSM Includes 6 thru 11 Z000 005 6 Power Sup...

Page 20: ...IP 13 UV Sterilizer Housing with unions E50S 50 WATT 209050 E80S 80 WATT 209080 E120S 120 WATT 209120 E150S 150 WATT 209150 KITS ITEM Quartz Sleeve Module QSM Includes 6 thru 11 Z000 005 6 Power Supp...

Page 21: ...21 SMART UV UV DISINFECTION STERILIZER Installation and User s Guide NOTES...

Page 22: ...22 SMART UV UV DISINFECTION STERILIZER Installation and User s Guide NOTES...

Page 23: ...23 SMART UV UV DISINFECTION STERILIZER Installation and User s Guide NOTES...

Page 24: ...popka Blvd Apopka FL 32703 USA Phone 407 886 3939 Web PentairAES com 2018 Pentair Aquatic Eco Systems Inc All rights reserved This document is subject to change without notice P N 02934 INS SMART Rev...

Reviews: