13
SMART UV® UV DISINFECTION STERILIZER Installation and User's Guide
INSTALLATION
2. After a successful leak test and without the power
supply connected to a control box, attach the
lamp’s 4-pins to the power cord’s white 4-pin
Connector (4), then slide the UV lamp back into the
quartz sleeve.
3.
Whether the SMART UV
®
Disinfection Sterilizer
vessel is mounted horizontally or vertically, care
should be taken when installing the UV lamp into
the vessel’s quartz sleeve. Vertical installations
require extra attention to eliminate the chance
of the lamp dropping into the quartz sleeve and
breaking.
4. With the UV lamp/power cord connection complete
and the lamp entirely inside the quartz sleeve,
carefully screw down the Gray Power Supply
Adapter (3) onto the Clear Quartz Sleeve Module
(6); hand tighten only.
5. Screw down the Black Power Supply Jamb Nut (4)
until it makes contact with the Clear Quartz Sleeve
Module (6).
NOTE
: By loosening the
3/8
inch Threaded Watertight
Cord Connector (5), Power Cord adjustments can be
made. Make sure the
3/8
inch Threaded Watertight
Cord Connector’s gasket is properly in place before
retightening.
NOTE
: If you do not have the Black Power Supply
Jamb Nut (4) back far enough before tightening the
Gray Power Supply Adapter (3), the gray adapter
will not make contact with the power supply gasket
and will enable outside moisture to enter the quartz
sleeve assembly and cause a system failure.