SMART UV® UV DISINFECTION STERILIZER Installation and User's Guide

Mounting the Power Supply

Depending on the style of power supply cylinder or 
rectangle the SMART UV

®

 system’s power supply can 

be mounted two ways, mounting tabs at the corner 
of the ballast or using the mounting clamps for the 
cylinder type of ballast. The power supply should 
always be mounted to a surface that is sheltered from 
rain, splashing, heavy condensation or any other kind 
of prolonged contact with water.

NOTE

: DO NOT mount the power supply in an 

extremely confined space where heat and moisture 
can be retained.

Your UV system will include one of two different 
power supplies based on the wattage of your unit:

•  

50W, 80W and 120W UV systems

 include a 

rectangular power supply. Four screws, one in 
each corner of the power supply, secure the power 
supply to the wall or shelf.

•  

150W UV systems

 include a cylindrical power 

supply that must be mounted with the two pipe 
clips packaged with the unit.

A single screw at the base of the pipe clip secures it 
to the wall or shelf. The power supply is then locked 
into the pipe clip by securing the retaining strap onto 
the clip.

Mandatory Leak Test

A leak test should be performed each time the quartz 
sleeve is installed inside the unit’s vessel or when the 
quartz sleeve or gaskets are replaced [Once annually]. 
Performing a leak test is a precautionary measure 
that will determine whether or not the critical seal 
between the quartz sleeve and quartz sleeve module 
has been achieved.

Failure to achieve a proper quartz sleeve/quartz 
sleeve module seal during SMART UV Disinfection 
Sterilizer operation will allow water to leak into the 
inside of the quartz sleeve, potentially damaging the 
UV lamp and other electrical components, which 
could develop into dangerous situations.

IMPORTANT NOTE: 

Failure to perform a leak test 

could lead to conditions that will void your product 
warranty.

To Perform Mandatory Leak Test:

1.  Prepare the UV system for permanent operation 

by plumbing it in-line, into a filter system using the 
plumbing hardware of your choice. If PVC glue is 
used, follow the glue manufacturer’s instructions.

2.  If UV lamp is installed, with the unit plumbed for 

operation and the clear quartz sleeve module 
securely in place, remove the UV lamp from the 
quartz sleeve module.

3.  

Roll-up a few paper towels creating a core 
approximately 

3/4

 inch diameter, 10-inches long 

then slide into the open quartz sleeve module port. 
Insert about 6-inches of the paper towel core down 
into the quartz sleeve, as shown.

4.  With the paper towel in place, turn on the pump 

and recirculate water through the UV vessel for at 
least thirty (30) minutes.

5.  

After thirty (30) minutes of recirculating water 
through the UV vessel, remove the paper towels 
from the quartz sleeve module. Inspect closely for 
moisture. If the paper towel is completely dry, your 
leak test is complete and successful.

If moisture is detected on the paper towel the quartz 
sleeve’s rubber gasket and O-ring have failed to 
achieve a seal and must be re-assembled; repeat 
the leak test until a seal is achieved. See page 4 for 
assembly instructions.

INSTALLATION

Summary of Contents for SMART UV E120S

Page 1: ...IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS SMART UV UV DISINFECTION STERILIZER INSTALLATION AND USER S GUIDE...

Page 2: ...are not used to indicate an affiliation or endorsement between the owners of these names and brands and Pentair Aquatic Eco Systems Inc Those names and brands may be the trademarks or registered trad...

Page 3: ...uartz Sleeve Assembly and Installation 9 Sterilizer Installation and Operation 10 Typical Installation 10 Mounting the Vessel 10 Mounting the Power Supply 11 Mandatory Leak Test 11 Electrical Connecti...

Page 4: ...missing ordamaged When installing and using this electrical equipment basic safety precautions should always be followed include the following FAILURE TO FOLLOW ALL INSTRUCTIONS AND WARNINGS CAN RESU...

Page 5: ...ay overheat Care should be taken to arrange the cord so that it will not be tripped overor pulled If in doubt consult a qualified electrician Warping of the UV body may occurwhen left in direct sunlig...

Page 6: ...t the highest UV C output conversion among all UV lamps UL listed for indoor and outdoor use fresh and salt water use Long lasting GPH T5 and GPH T6 UV lamps 9 000 hours to 80 efficiency Protective Qu...

Page 7: ...EU18 U EU25 U EU40 EU65P SMART UV HO Sterilizer Models Part Numbers E50S E80S E120S E150S Power Supplies The power supply can either be a cylinder POD or a rectangle style Below are the ballasts that...

Page 8: ...ontact the place of original purchase immediately NOTE Save the corrugated lamp packaging after unpacking the UV lamp Storing the lamp and or quartz sleeve in this packaging while performing maintenan...

Page 9: ...sleeve module use your index finger to ensure that the open end of the quartz sleeve mates smoothly with the inside lip of the clear quartz sleeve module this signifies a good fit See Photo A 5 With...

Page 10: ...important role in the unit s performance and degree of safety We STRONGLY RECOMMEND that you follow these instructions and guidelines precisely Any deviation from these mounting instructions will voi...

Page 11: ...uartz sleeve module has been achieved Failure to achieve a proper quartz sleeve quartz sleeve module seal during SMART UV Disinfection Sterilizer operation will allow water to leak into the inside of...

Page 12: ...er or pulled If in doubt consult a qualified electrician GFCI s are designed to sense an imbalance in electrical current flow within the main electrical leads leakage current When this imbalance maxim...

Page 13: ...UV lamp power cord connection complete and the lamp entirely inside the quartz sleeve carefully screw down the Gray Power Supply Adapter 3 onto the Clear Quartz Sleeve Module 6 hand tighten only 5 Scr...

Page 14: ...al tape on all threaded connections Larger Sized Ponds above 5 000 Gallons Using Surface Skimmer and Pressurized Filter This system is simple yet it achieves critical filtering goals such as good wate...

Page 15: ...water flow meter manufacturer s instructions for proper installation and operation See Diagram 4 NOTE Before gluing piping or reducer bushing into the UV s union or socket remove the quartz sleeve ass...

Page 16: ...sits If using muriatic acid a ratio of four parts water to one part acid should suffice Always introduce acid to the water and never introduce the water to the acid Muriatic acid is corrosive and can...

Page 17: ...n solder to make them firm enough to push back in the new lamp connector NOTE Clean away any residual flux off of the wires before assembling them into the lamp connector 7 Using a new 4 pin lamp conn...

Page 18: ...aker is tripping 1 Immediately disconnect power to the SMART UV Disinfection Sterilizer 2 Turn off the pool pump at the circuit breaker and be sure all flow to the unit has been stopped 3 Refer to pag...

Page 19: ...unions EU18 U 18 WATT 960359 EU25 U 25 WATT 20425 EU40 40 WATT 20440 EU65P 65 WATT 20465 EU80P 80 WATT NA EU130P 130 WATT NA KITS ITEM Quartz Sleeve Module QSM Includes 6 thru 11 Z000 005 6 Power Sup...

Page 20: ...IP 13 UV Sterilizer Housing with unions E50S 50 WATT 209050 E80S 80 WATT 209080 E120S 120 WATT 209120 E150S 150 WATT 209150 KITS ITEM Quartz Sleeve Module QSM Includes 6 thru 11 Z000 005 6 Power Supp...

Page 21: ...21 SMART UV UV DISINFECTION STERILIZER Installation and User s Guide NOTES...

Page 22: ...22 SMART UV UV DISINFECTION STERILIZER Installation and User s Guide NOTES...

Page 23: ...23 SMART UV UV DISINFECTION STERILIZER Installation and User s Guide NOTES...

Page 24: ...popka Blvd Apopka FL 32703 USA Phone 407 886 3939 Web PentairAES com 2018 Pentair Aquatic Eco Systems Inc All rights reserved This document is subject to change without notice P N 02934 INS SMART Rev...

Reviews: