background image

12

SMART UV® UV DISINFECTION STERILIZER Installation and User's Guide

INSTALLATION

Electrical Requirements

The electrical requirements for the UV sterilizer are 
marked on the unit’s power supply label (Ex. 120VAC 
50/60Hz.). The unit must be plugged into a well-
grounded electrical outlet.

  Do not attempt to cut the ground post 

off of the 3-prong plug, doing so will void the unit’s 
warranty.

This product must be grounded. If the unit should 
fail electrically, grounding provides a path of least 
resistance for electric current to pass to reduce 
the risk of electric shock. This product’s cord is 
equipped with an equipment-grounding conductor 
and a grounding plug. The plug must be plugged 
into an appropriate outlet that is properly installed 
and grounded in accordance with all local codes and 
ordinances. If in doubt consult a qualified electrician.

  DO NOT operate this equipment with 

timing devices.

  Improper connection of the equipment-

grounding conductor can result in a risk of 
electrocution. Check with a qualified electrician or 
service personnel if unsure that the outlet is properly 
grounded. Do not product’s plug. If it will not fit into 
the electrical outlet, have a proper outlet installed by 
a qualified electrician. Type of plug adapter with this 
product.

Ground Fault Circuit Interrupter  
(GFCI) Protection

  

This unit must be wired in conjunction 

with a properly grounded, Ground Fault Circuit 
Interrupter (GFCI).

 Only three (3) wire grounded 

cables suitable for outdoor use should be used to 
connect this unit. If joining cables for outdoor use, a 
suitable watertight cable connector must be used. If 
an extension cord is necessary, a cord with a proper 
rating should be used. A cord rated for fewer amperes 
or watts than the appliance’s rating may overheat. 
Care should be taken to arrange the cord so that it 
will not be tripped over or pulled. If in doubt consult a 
qualified electrician.

GFCI’s are designed to sense an imbalance in 
electrical current flow within the main electrical leads 
(leakage current). When this imbalance (maximum 5 
mA per UL) occurs in the main leads, a comparator 

within the GFCI outlet generates a trip signal which is 
applied to a coil that trips the main (normally closed) 
contacts. These contacts open and break the circuit.

Ghost Trips

Consider that all GFCI’s must trip at a leakage current 
of 5 ma. GFCI “Ghost Trips” are caused by electrical 
devices that have small electrical leakage current to 
ground. Multiple outlets protected by one GFCI allow 
for potential cumulative leakage currents caused by 
multiple appliances each leaking small amounts of 
current.

Example:

 One pump plugged into an outlet that is 

part of a four outlet branch protected by one GFCI 
will not trip the GFCI with its 2 mA leakage current. 
However, two pumps and a UV with a cumulative 
leakage current of 7 mA will trip the GFCI. This is a 
common problem.

The solution to the GFCI “Ghost Trip” problem is to 
operate the device on its own GFCI protected outlet, 
or, remove other devices from the GFCI protected 
branch of outlets. If the GFCI is over ten years old, 
you may want to consider replacing it.

UV Lamp Installation

Lamp Styles

UV lamps are manufactured with color coded ceramic 
bases. White-capped UV lamps signify a Standard-
Output UV lamp while red-capped UV lamps signify a 
High-Output UV lamp.

Power Cord Adjustment

There should be 4-inches of cord between the Gray 
Adapter (3) and the 4-pin Lamp Connector (1). The 
4-inch cord distance positions the lamp properly 
inside the quartz sleeve.

1.   The 

3/8

 inch Threaded Watertight Cord Connector 

(1) is adjustable. Loosen it gently move the cord 
through it. Care must be taken when retightening. 
If the Connector’s Rubber Gasket Seal is dislodged 
during cord adjustment please make sure that it 
is properly re-seated inside the male threaded 
portion of the connector.

4 Inches between Gray Adapter (3) and 4-Pin Connector (4)

Summary of Contents for SMART UV E120S

Page 1: ...IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS SMART UV UV DISINFECTION STERILIZER INSTALLATION AND USER S GUIDE...

Page 2: ...are not used to indicate an affiliation or endorsement between the owners of these names and brands and Pentair Aquatic Eco Systems Inc Those names and brands may be the trademarks or registered trad...

Page 3: ...uartz Sleeve Assembly and Installation 9 Sterilizer Installation and Operation 10 Typical Installation 10 Mounting the Vessel 10 Mounting the Power Supply 11 Mandatory Leak Test 11 Electrical Connecti...

Page 4: ...missing ordamaged When installing and using this electrical equipment basic safety precautions should always be followed include the following FAILURE TO FOLLOW ALL INSTRUCTIONS AND WARNINGS CAN RESU...

Page 5: ...ay overheat Care should be taken to arrange the cord so that it will not be tripped overor pulled If in doubt consult a qualified electrician Warping of the UV body may occurwhen left in direct sunlig...

Page 6: ...t the highest UV C output conversion among all UV lamps UL listed for indoor and outdoor use fresh and salt water use Long lasting GPH T5 and GPH T6 UV lamps 9 000 hours to 80 efficiency Protective Qu...

Page 7: ...EU18 U EU25 U EU40 EU65P SMART UV HO Sterilizer Models Part Numbers E50S E80S E120S E150S Power Supplies The power supply can either be a cylinder POD or a rectangle style Below are the ballasts that...

Page 8: ...ontact the place of original purchase immediately NOTE Save the corrugated lamp packaging after unpacking the UV lamp Storing the lamp and or quartz sleeve in this packaging while performing maintenan...

Page 9: ...sleeve module use your index finger to ensure that the open end of the quartz sleeve mates smoothly with the inside lip of the clear quartz sleeve module this signifies a good fit See Photo A 5 With...

Page 10: ...important role in the unit s performance and degree of safety We STRONGLY RECOMMEND that you follow these instructions and guidelines precisely Any deviation from these mounting instructions will voi...

Page 11: ...uartz sleeve module has been achieved Failure to achieve a proper quartz sleeve quartz sleeve module seal during SMART UV Disinfection Sterilizer operation will allow water to leak into the inside of...

Page 12: ...er or pulled If in doubt consult a qualified electrician GFCI s are designed to sense an imbalance in electrical current flow within the main electrical leads leakage current When this imbalance maxim...

Page 13: ...UV lamp power cord connection complete and the lamp entirely inside the quartz sleeve carefully screw down the Gray Power Supply Adapter 3 onto the Clear Quartz Sleeve Module 6 hand tighten only 5 Scr...

Page 14: ...al tape on all threaded connections Larger Sized Ponds above 5 000 Gallons Using Surface Skimmer and Pressurized Filter This system is simple yet it achieves critical filtering goals such as good wate...

Page 15: ...water flow meter manufacturer s instructions for proper installation and operation See Diagram 4 NOTE Before gluing piping or reducer bushing into the UV s union or socket remove the quartz sleeve ass...

Page 16: ...sits If using muriatic acid a ratio of four parts water to one part acid should suffice Always introduce acid to the water and never introduce the water to the acid Muriatic acid is corrosive and can...

Page 17: ...n solder to make them firm enough to push back in the new lamp connector NOTE Clean away any residual flux off of the wires before assembling them into the lamp connector 7 Using a new 4 pin lamp conn...

Page 18: ...aker is tripping 1 Immediately disconnect power to the SMART UV Disinfection Sterilizer 2 Turn off the pool pump at the circuit breaker and be sure all flow to the unit has been stopped 3 Refer to pag...

Page 19: ...unions EU18 U 18 WATT 960359 EU25 U 25 WATT 20425 EU40 40 WATT 20440 EU65P 65 WATT 20465 EU80P 80 WATT NA EU130P 130 WATT NA KITS ITEM Quartz Sleeve Module QSM Includes 6 thru 11 Z000 005 6 Power Sup...

Page 20: ...IP 13 UV Sterilizer Housing with unions E50S 50 WATT 209050 E80S 80 WATT 209080 E120S 120 WATT 209120 E150S 150 WATT 209150 KITS ITEM Quartz Sleeve Module QSM Includes 6 thru 11 Z000 005 6 Power Supp...

Page 21: ...21 SMART UV UV DISINFECTION STERILIZER Installation and User s Guide NOTES...

Page 22: ...22 SMART UV UV DISINFECTION STERILIZER Installation and User s Guide NOTES...

Page 23: ...23 SMART UV UV DISINFECTION STERILIZER Installation and User s Guide NOTES...

Page 24: ...popka Blvd Apopka FL 32703 USA Phone 407 886 3939 Web PentairAES com 2018 Pentair Aquatic Eco Systems Inc All rights reserved This document is subject to change without notice P N 02934 INS SMART Rev...

Reviews: