OPERATION

SMART UV

®

 Installation and Operation

SMART UV Systems UV Sterilizers are used in 
a variety of applications to control waterborne 
pathogens. Pentair encourages the consideration of 
the installation/operation recommendations provided 
here.

Suspended solid waste will absorb UV light and 
reduce the UV transmittance through water. By 
operating the SMART UV after the mechanical filter, 
the unit’s overall performance will be increased.

When operating SMART UV sterilizers please 
consider the recommended water flow rates.

Pond Installation Configurations

Small to Moderately Sized Ponds (up to 5,000 
Gallons) Using Skimmers and Falls

Placing the UV between the skimmer box and the 
filter ensures that pre-filtered water reaches the 
UV, increasing its performance while reducing 
maintenance.

Often the capacity of the pump exceeds the capacity 
of the UV. If this is the case, install a bypass manifold. 
Be sure that the skimmer is equipped with mechanical 
filtering capacity. See 

Diagram 1

.

NOTE

: Before gluing piping or reducer bushing into 

the UV’s union or socket, remove the quartz sleeve 
assembly to prevent glue from dripping onto the 
quartz sleeve.

NOTE

: Use threaded seal tape on all threaded 

connections.

Larger Sized Ponds (above 5,000 Gallons) Using 
Surface Skimmer and Pressurized Filter

This system is simple yet it achieves critical filtering 
goals, such as good water circulation for increased 
solid waste suspension. The bottom drain/surface 
skimming capabilities ensure maximum waste 
removal. See 

Diagram 2

.

The SMART UV System UV Sterilizer is positioned 
after the mechanical filter where it can receive only 
solid waste free water, optimizing UV transmittance/ 
performance. Notice the 3-way valve that regulates 
suction from the skimmer and drain to the pump, 
allowing flow control.

Next, multiple “clean water returns” improve 
circulation, suspending solid waste and helping it to 
find the filter. If you have a flow rate that exceeds the 
UV’s, install a by-pass manifold. See 

Diagram 1

.

NOTE

: Before gluing piping or reducer bushing into 

the UV’s union or socket, remove the quartz sleeve 
assembly to prevent glue from dripping onto the 
quartz sleeve.

NOTE

: Use threaded seal tape on all threaded 

connections.

Aquarium Installation Configurations

Canister Filter/Aquarium Installation

Pressurized Canister filters are commonly used with 
small freshwater/saltwater aquariums. 

Diagram 3

 

shows a SMART UV model.

It is important to match the Canister Filter’s flow rate 
to the capacity of the SMART UV. If this is not feasible, 
use a bypass manifold (see 

Diagram 5

 on page 

14). To prevent back-siphoning, consider installing 

Summary of Contents for SMART UV E120S

Page 1: ...IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS SMART UV UV DISINFECTION STERILIZER INSTALLATION AND USER S GUIDE...

Page 2: ...are not used to indicate an affiliation or endorsement between the owners of these names and brands and Pentair Aquatic Eco Systems Inc Those names and brands may be the trademarks or registered trad...

Page 3: ...uartz Sleeve Assembly and Installation 9 Sterilizer Installation and Operation 10 Typical Installation 10 Mounting the Vessel 10 Mounting the Power Supply 11 Mandatory Leak Test 11 Electrical Connecti...

Page 4: ...missing ordamaged When installing and using this electrical equipment basic safety precautions should always be followed include the following FAILURE TO FOLLOW ALL INSTRUCTIONS AND WARNINGS CAN RESU...

Page 5: ...ay overheat Care should be taken to arrange the cord so that it will not be tripped overor pulled If in doubt consult a qualified electrician Warping of the UV body may occurwhen left in direct sunlig...

Page 6: ...t the highest UV C output conversion among all UV lamps UL listed for indoor and outdoor use fresh and salt water use Long lasting GPH T5 and GPH T6 UV lamps 9 000 hours to 80 efficiency Protective Qu...

Page 7: ...EU18 U EU25 U EU40 EU65P SMART UV HO Sterilizer Models Part Numbers E50S E80S E120S E150S Power Supplies The power supply can either be a cylinder POD or a rectangle style Below are the ballasts that...

Page 8: ...ontact the place of original purchase immediately NOTE Save the corrugated lamp packaging after unpacking the UV lamp Storing the lamp and or quartz sleeve in this packaging while performing maintenan...

Page 9: ...sleeve module use your index finger to ensure that the open end of the quartz sleeve mates smoothly with the inside lip of the clear quartz sleeve module this signifies a good fit See Photo A 5 With...

Page 10: ...important role in the unit s performance and degree of safety We STRONGLY RECOMMEND that you follow these instructions and guidelines precisely Any deviation from these mounting instructions will voi...

Page 11: ...uartz sleeve module has been achieved Failure to achieve a proper quartz sleeve quartz sleeve module seal during SMART UV Disinfection Sterilizer operation will allow water to leak into the inside of...

Page 12: ...er or pulled If in doubt consult a qualified electrician GFCI s are designed to sense an imbalance in electrical current flow within the main electrical leads leakage current When this imbalance maxim...

Page 13: ...UV lamp power cord connection complete and the lamp entirely inside the quartz sleeve carefully screw down the Gray Power Supply Adapter 3 onto the Clear Quartz Sleeve Module 6 hand tighten only 5 Scr...

Page 14: ...al tape on all threaded connections Larger Sized Ponds above 5 000 Gallons Using Surface Skimmer and Pressurized Filter This system is simple yet it achieves critical filtering goals such as good wate...

Page 15: ...water flow meter manufacturer s instructions for proper installation and operation See Diagram 4 NOTE Before gluing piping or reducer bushing into the UV s union or socket remove the quartz sleeve ass...

Page 16: ...sits If using muriatic acid a ratio of four parts water to one part acid should suffice Always introduce acid to the water and never introduce the water to the acid Muriatic acid is corrosive and can...

Page 17: ...n solder to make them firm enough to push back in the new lamp connector NOTE Clean away any residual flux off of the wires before assembling them into the lamp connector 7 Using a new 4 pin lamp conn...

Page 18: ...aker is tripping 1 Immediately disconnect power to the SMART UV Disinfection Sterilizer 2 Turn off the pool pump at the circuit breaker and be sure all flow to the unit has been stopped 3 Refer to pag...

Page 19: ...unions EU18 U 18 WATT 960359 EU25 U 25 WATT 20425 EU40 40 WATT 20440 EU65P 65 WATT 20465 EU80P 80 WATT NA EU130P 130 WATT NA KITS ITEM Quartz Sleeve Module QSM Includes 6 thru 11 Z000 005 6 Power Sup...

Page 20: ...IP 13 UV Sterilizer Housing with unions E50S 50 WATT 209050 E80S 80 WATT 209080 E120S 120 WATT 209120 E150S 150 WATT 209150 KITS ITEM Quartz Sleeve Module QSM Includes 6 thru 11 Z000 005 6 Power Supp...

Page 21: ...21 SMART UV UV DISINFECTION STERILIZER Installation and User s Guide NOTES...

Page 22: ...22 SMART UV UV DISINFECTION STERILIZER Installation and User s Guide NOTES...

Page 23: ...23 SMART UV UV DISINFECTION STERILIZER Installation and User s Guide NOTES...

Page 24: ...popka Blvd Apopka FL 32703 USA Phone 407 886 3939 Web PentairAES com 2018 Pentair Aquatic Eco Systems Inc All rights reserved This document is subject to change without notice P N 02934 INS SMART Rev...

Reviews: